•Sodium silicate-based sealant was investigated for use in a recuperator.•Small-scale clamped plate-style recuperator designs were built and tested.•A cold-side effectiveness of 82.5% was found for the recuperator core in experiment.•A total pressure loss of 24.9 kPa was found for the recuperator co...
Gespeichert in:
Veröffentlicht in: | Applied thermal engineering 2020-08, Vol.177, p.115439, Article 115439 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | •Sodium silicate-based sealant was investigated for use in a recuperator.•Small-scale clamped plate-style recuperator designs were built and tested.•A cold-side effectiveness of 82.5% was found for the recuperator core in experiment.•A total pressure loss of 24.9 kPa was found for the recuperator core in experiment.•A validated mathematical model was applied to a solar Brayton cycle recuperator.
A large, efficient recuperator is required for high cycle efficiency in a solar Brayton cycle (STBC) with an open-cavity solar receiver and air as working fluid. A recuperator often requires complex and costly manufacturing methods. In this work, a clamped plate-type recuperator with a metal gasket is investigated, together with a low-cost high-temperature sodium silicate-based sealant. Experimental investigations were performed to validate a mathematical model using a novel bone-shape design as well as a wide-channel design. The high-temperature sealant worked well on the bone-shape recuperator; however, a leak occurred on the hot-side header tube of the wide-channel recuperator. For the recuperator core of the wide-channel test rig, a cold-side effectiveness of 82.5% and a total pressure loss of 24.9 kPa were found at an average mass flow rate of 0.74 g/s per channel. The validated mathematical model was used in a parametric study to analyse the performance of the recuperator in an STBC by taking the stress and deflection of the plates into consideration. Results show that, for a total mass flow rate of 0.06 kg/s, a cold-side effectiveness of 90% and total pressure loss of less than 5% could be achieved, if a spacer is implemented to prevent deflection. |
---|---|
ISSN: | 1359-4311 1873-5606 |
DOI: | 10.1016/j.applthermaleng.2020.115439 |