The Effect of Different Irrigation Solutions on the Accuracy of Two Electronic Apex Locators in Locating Artificial Root Perforations
Objective: This study aimed to assess the accuracy of the Raypex 6 (VDW GmbH, Munich, Germany) and Root ZX mini (J. Morita Corp., Tokyo, Japan) electronic apex locators (EALs) with regard to detecting root perforations in dry conditions and in the presence of irrigation solutions [2.5% sodium hypoch...
Gespeichert in:
Veröffentlicht in: | Meandros medical and dental journal 2020-08, Vol.21 (2), p.134-139 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 139 |
---|---|
container_issue | 2 |
container_start_page | 134 |
container_title | Meandros medical and dental journal |
container_volume | 21 |
creator | Uğur Aydın, Zeliha Altunbaş, Demet Meşeci, Büşra |
description | Objective: This study aimed to assess the accuracy of the Raypex 6 (VDW GmbH,
Munich, Germany) and Root ZX mini (J. Morita Corp., Tokyo, Japan) electronic apex
locators (EALs) with regard to detecting root perforations in dry conditions and
in the presence of irrigation solutions [2.5% sodium hypochlorite (NaOCl), 17%
ethylenediaminetetraacetic acid (EDTA) and Qmix].
Materials and Methods: Twenty single-rooted human teeth were perforated
artificially with a 1 mm diameter in the middle region. The actual canal lengths
up to the perforation site were determined, and then the teeth were embedded in
an alginate mold. The electronic measurements of the perforations were obtained
using a size #20 K-file for each EAL in various conditions.
Results: There were significant differences between the different canal conditions
in the Raypex 6 group (p0.05). There was a statistically significant difference (p0.05).
Conclusion: Under the conditions of this study, both apex locators detected
root canal perforations within a clinically acceptable (range of -0.18 to 0.31mm)
distance from the coronal border of the perforation region. Irrigation solutions
within the root canal affected the accuracy of Raypex 6, but not of Root ZX mini. |
doi_str_mv | 10.4274/meandros.galenos.2020.41196 |
format | Article |
fullrecord | <record><control><sourceid>proquest_ideal</sourceid><recordid>TN_cdi_proquest_journals_2440899558</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2440899558</sourcerecordid><originalsourceid>FETCH-LOGICAL-c251t-41aed58b7542531964c46516bf2e899ce28852dab2b96e09a5cbddd40323c2713</originalsourceid><addsrcrecordid>eNpNkd1KAzEQhRdRsGjfIdAbb7Ym2WR_8GppVy0sKFqvQzabrSnbpCZZtA_ge5v-iF7NGebMGYYviiYITgnOyO1Gct1a46Yr3ksdKoY4jBAq0rNohBEp4gKmyfk_fRmNnVtDCFGW0iJJR9H38l2Cquuk8MB0YK6CtFJ7sLBWrbhXRoNX0w974UBofPCXQgyWi91-Y_lpQNWHdWu0EqDcyi9QG8G9sQ4ofdRKr0BpveqUULwHL8Z48CxtZ-zhgruOLjreOzk-1avo7b5azh7j-ulhMSvrWGCKfEwQly3Nm4wSTJPwJxEkpShtOizzohAS5znFLW9wU6QSFpyKpm1bAhOcCJyh5CqaHHO31nwM0nm2NoPV4STDhMCQQWkeXDdHl2ol743ulZZ_xsW8KmuGUIYOgXdHqwggnJUd21q14XbHEGR7SuyXEjtRYntK7EAp-QHw14vG</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2440899558</pqid></control><display><type>article</type><title>The Effect of Different Irrigation Solutions on the Accuracy of Two Electronic Apex Locators in Locating Artificial Root Perforations</title><source>Alma/SFX Local Collection</source><creator>Uğur Aydın, Zeliha ; Altunbaş, Demet ; Meşeci, Büşra</creator><contributor>Turan,Yasemin</contributor><creatorcontrib>Uğur Aydın, Zeliha ; Altunbaş, Demet ; Meşeci, Büşra ; Turan,Yasemin</creatorcontrib><description>Objective: This study aimed to assess the accuracy of the Raypex 6 (VDW GmbH,
Munich, Germany) and Root ZX mini (J. Morita Corp., Tokyo, Japan) electronic apex
locators (EALs) with regard to detecting root perforations in dry conditions and
in the presence of irrigation solutions [2.5% sodium hypochlorite (NaOCl), 17%
ethylenediaminetetraacetic acid (EDTA) and Qmix].
Materials and Methods: Twenty single-rooted human teeth were perforated
artificially with a 1 mm diameter in the middle region. The actual canal lengths
up to the perforation site were determined, and then the teeth were embedded in
an alginate mold. The electronic measurements of the perforations were obtained
using a size #20 K-file for each EAL in various conditions.
Results: There were significant differences between the different canal conditions
in the Raypex 6 group (p<0.05), but no significant differences in the Root ZX mini
group (p>0.05). There was a statistically significant difference (p<0.05) between the
two EALs in the presence of EDTA solution, but no statistically significant difference
between the accuracy of two EALs in the presence of other solutions and in the dry
canal condition (p>0.05).
Conclusion: Under the conditions of this study, both apex locators detected
root canal perforations within a clinically acceptable (range of -0.18 to 0.31mm)
distance from the coronal border of the perforation region. Irrigation solutions
within the root canal affected the accuracy of Raypex 6, but not of Root ZX mini.</description><identifier>ISSN: 2149-9063</identifier><identifier>EISSN: 2149-9063</identifier><identifier>DOI: 10.4274/meandros.galenos.2020.41196</identifier><language>eng</language><publisher>Aydın: Adnan Menderes Üniversitesi</publisher><subject>Accuracy ; Acetic acid ; Alginic acid ; Edetic acid ; Endodontics ; Lavage ; Root canals ; Sodium hypochlorite ; Statistical analysis ; Teeth ; Tıp</subject><ispartof>Meandros medical and dental journal, 2020-08, Vol.21 (2), p.134-139</ispartof><rights>2020. This work is published under https://creativecommons.org/licenses/by-nc/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><orcidid>0000-0002-8864-3953 ; 0000-0002-1773-9114 ; 0000-0002-7532-4785</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27915,27916</link.rule.ids></links><search><contributor>Turan,Yasemin</contributor><creatorcontrib>Uğur Aydın, Zeliha</creatorcontrib><creatorcontrib>Altunbaş, Demet</creatorcontrib><creatorcontrib>Meşeci, Büşra</creatorcontrib><title>The Effect of Different Irrigation Solutions on the Accuracy of Two Electronic Apex Locators in Locating Artificial Root Perforations</title><title>Meandros medical and dental journal</title><description>Objective: This study aimed to assess the accuracy of the Raypex 6 (VDW GmbH,
Munich, Germany) and Root ZX mini (J. Morita Corp., Tokyo, Japan) electronic apex
locators (EALs) with regard to detecting root perforations in dry conditions and
in the presence of irrigation solutions [2.5% sodium hypochlorite (NaOCl), 17%
ethylenediaminetetraacetic acid (EDTA) and Qmix].
Materials and Methods: Twenty single-rooted human teeth were perforated
artificially with a 1 mm diameter in the middle region. The actual canal lengths
up to the perforation site were determined, and then the teeth were embedded in
an alginate mold. The electronic measurements of the perforations were obtained
using a size #20 K-file for each EAL in various conditions.
Results: There were significant differences between the different canal conditions
in the Raypex 6 group (p<0.05), but no significant differences in the Root ZX mini
group (p>0.05). There was a statistically significant difference (p<0.05) between the
two EALs in the presence of EDTA solution, but no statistically significant difference
between the accuracy of two EALs in the presence of other solutions and in the dry
canal condition (p>0.05).
Conclusion: Under the conditions of this study, both apex locators detected
root canal perforations within a clinically acceptable (range of -0.18 to 0.31mm)
distance from the coronal border of the perforation region. Irrigation solutions
within the root canal affected the accuracy of Raypex 6, but not of Root ZX mini.</description><subject>Accuracy</subject><subject>Acetic acid</subject><subject>Alginic acid</subject><subject>Edetic acid</subject><subject>Endodontics</subject><subject>Lavage</subject><subject>Root canals</subject><subject>Sodium hypochlorite</subject><subject>Statistical analysis</subject><subject>Teeth</subject><subject>Tıp</subject><issn>2149-9063</issn><issn>2149-9063</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><sourceid>GNUQQ</sourceid><recordid>eNpNkd1KAzEQhRdRsGjfIdAbb7Ym2WR_8GppVy0sKFqvQzabrSnbpCZZtA_ge5v-iF7NGebMGYYviiYITgnOyO1Gct1a46Yr3ksdKoY4jBAq0rNohBEp4gKmyfk_fRmNnVtDCFGW0iJJR9H38l2Cquuk8MB0YK6CtFJ7sLBWrbhXRoNX0w974UBofPCXQgyWi91-Y_lpQNWHdWu0EqDcyi9QG8G9sQ4ofdRKr0BpveqUULwHL8Z48CxtZ-zhgruOLjreOzk-1avo7b5azh7j-ulhMSvrWGCKfEwQly3Nm4wSTJPwJxEkpShtOizzohAS5znFLW9wU6QSFpyKpm1bAhOcCJyh5CqaHHO31nwM0nm2NoPV4STDhMCQQWkeXDdHl2ol743ulZZ_xsW8KmuGUIYOgXdHqwggnJUd21q14XbHEGR7SuyXEjtRYntK7EAp-QHw14vG</recordid><startdate>20200801</startdate><enddate>20200801</enddate><creator>Uğur Aydın, Zeliha</creator><creator>Altunbaş, Demet</creator><creator>Meşeci, Büşra</creator><general>Adnan Menderes Üniversitesi</general><general>Galenos Publishing House</general><scope>AAYXX</scope><scope>CITATION</scope><scope>IEBAR</scope><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>8FE</scope><scope>8FH</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BBNVY</scope><scope>BENPR</scope><scope>BHPHI</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>HCIFZ</scope><scope>K9.</scope><scope>LK8</scope><scope>M0S</scope><scope>M7P</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><orcidid>https://orcid.org/0000-0002-8864-3953</orcidid><orcidid>https://orcid.org/0000-0002-1773-9114</orcidid><orcidid>https://orcid.org/0000-0002-7532-4785</orcidid></search><sort><creationdate>20200801</creationdate><title>The Effect of Different Irrigation Solutions on the Accuracy of Two Electronic Apex Locators in Locating Artificial Root Perforations</title><author>Uğur Aydın, Zeliha ; Altunbaş, Demet ; Meşeci, Büşra</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c251t-41aed58b7542531964c46516bf2e899ce28852dab2b96e09a5cbddd40323c2713</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Accuracy</topic><topic>Acetic acid</topic><topic>Alginic acid</topic><topic>Edetic acid</topic><topic>Endodontics</topic><topic>Lavage</topic><topic>Root canals</topic><topic>Sodium hypochlorite</topic><topic>Statistical analysis</topic><topic>Teeth</topic><topic>Tıp</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Uğur Aydın, Zeliha</creatorcontrib><creatorcontrib>Altunbaş, Demet</creatorcontrib><creatorcontrib>Meşeci, Büşra</creatorcontrib><collection>CrossRef</collection><collection>Idealonline online kütüphane - Journals</collection><collection>ProQuest Central (Corporate)</collection><collection>Health & Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Natural Science Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>Biological Science Collection</collection><collection>ProQuest Central</collection><collection>Natural Science Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>ProQuest Biological Science Collection</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>Biological Science Database</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><jtitle>Meandros medical and dental journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Uğur Aydın, Zeliha</au><au>Altunbaş, Demet</au><au>Meşeci, Büşra</au><au>Turan,Yasemin</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The Effect of Different Irrigation Solutions on the Accuracy of Two Electronic Apex Locators in Locating Artificial Root Perforations</atitle><jtitle>Meandros medical and dental journal</jtitle><date>2020-08-01</date><risdate>2020</risdate><volume>21</volume><issue>2</issue><spage>134</spage><epage>139</epage><pages>134-139</pages><issn>2149-9063</issn><eissn>2149-9063</eissn><abstract>Objective: This study aimed to assess the accuracy of the Raypex 6 (VDW GmbH,
Munich, Germany) and Root ZX mini (J. Morita Corp., Tokyo, Japan) electronic apex
locators (EALs) with regard to detecting root perforations in dry conditions and
in the presence of irrigation solutions [2.5% sodium hypochlorite (NaOCl), 17%
ethylenediaminetetraacetic acid (EDTA) and Qmix].
Materials and Methods: Twenty single-rooted human teeth were perforated
artificially with a 1 mm diameter in the middle region. The actual canal lengths
up to the perforation site were determined, and then the teeth were embedded in
an alginate mold. The electronic measurements of the perforations were obtained
using a size #20 K-file for each EAL in various conditions.
Results: There were significant differences between the different canal conditions
in the Raypex 6 group (p<0.05), but no significant differences in the Root ZX mini
group (p>0.05). There was a statistically significant difference (p<0.05) between the
two EALs in the presence of EDTA solution, but no statistically significant difference
between the accuracy of two EALs in the presence of other solutions and in the dry
canal condition (p>0.05).
Conclusion: Under the conditions of this study, both apex locators detected
root canal perforations within a clinically acceptable (range of -0.18 to 0.31mm)
distance from the coronal border of the perforation region. Irrigation solutions
within the root canal affected the accuracy of Raypex 6, but not of Root ZX mini.</abstract><cop>Aydın</cop><pub>Adnan Menderes Üniversitesi</pub><doi>10.4274/meandros.galenos.2020.41196</doi><tpages>6</tpages><orcidid>https://orcid.org/0000-0002-8864-3953</orcidid><orcidid>https://orcid.org/0000-0002-1773-9114</orcidid><orcidid>https://orcid.org/0000-0002-7532-4785</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2149-9063 |
ispartof | Meandros medical and dental journal, 2020-08, Vol.21 (2), p.134-139 |
issn | 2149-9063 2149-9063 |
language | eng |
recordid | cdi_proquest_journals_2440899558 |
source | Alma/SFX Local Collection |
subjects | Accuracy Acetic acid Alginic acid Edetic acid Endodontics Lavage Root canals Sodium hypochlorite Statistical analysis Teeth Tıp |
title | The Effect of Different Irrigation Solutions on the Accuracy of Two Electronic Apex Locators in Locating Artificial Root Perforations |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-14T21%3A15%3A15IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_ideal&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20Effect%20of%20Different%20Irrigation%20Solutions%20on%20the%20Accuracy%20of%20Two%20Electronic%20Apex%20Locators%20in%20Locating%20Artificial%20Root%20Perforations&rft.jtitle=Meandros%20medical%20and%20dental%20journal&rft.au=U%C4%9Fur%20Ayd%C4%B1n,%20Zeliha&rft.date=2020-08-01&rft.volume=21&rft.issue=2&rft.spage=134&rft.epage=139&rft.pages=134-139&rft.issn=2149-9063&rft.eissn=2149-9063&rft_id=info:doi/10.4274/meandros.galenos.2020.41196&rft_dat=%3Cproquest_ideal%3E2440899558%3C/proquest_ideal%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2440899558&rft_id=info:pmid/&rfr_iscdi=true |