Failure Investigation of a High-Temperature Cast Soot Blower Lance Tube Nozzle

Failure in the form of stress corrosion cracking has occurred on the SS304 lance tube soot blower. The hardness test showed high value for the area close to the failed region. The SEM test showed formation of heterogonous and porosity film on the surface. XRD indicated that the oxides determined wer...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of failure analysis and prevention 2020-08, Vol.20 (4), p.1124-1129
Hauptverfasser: Fatah, M. C., Putra, D. T., Kurniawan, B. A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Failure in the form of stress corrosion cracking has occurred on the SS304 lance tube soot blower. The hardness test showed high value for the area close to the failed region. The SEM test showed formation of heterogonous and porosity film on the surface. XRD indicated that the oxides determined were Fe 2 O 3 and Fe 3 O 4 . Metallographic of the lance tube revealed pitting as the stress concentrator. Pitting is caused by chloride (as chlorine) and SO 2− from the flue gas. SO 2− reacts with water to form acidic sodium bisulfate (NaHSO 4 ). Stress is generated from exposure of lance tube parts to high and low temperature during its service.
ISSN:1547-7029
1728-5674
1864-1245
DOI:10.1007/s11668-020-00914-w