The ENUBET positron tagger prototype: construction and testbeam performance

A prototype for the instrumented decay tunnel of ENUBET was tested in 2018 at the CERN East Area facility with charged particles up to 5 GeV. This detector is a longitudinal sampling calorimeter with lateral scintillation light readout. The calorimeter was equipped by an additional "t(0)-layer&...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of instrumentation 2020-08, Vol.15 (8), p.P08001-P08001, Article 08001
Hauptverfasser: Acerbi, F., Bonesini, M., Bramati, F., Branca, A., Brizzolari, C., Brunetti, G., Capelli, S., Carturan, S., Catanesi, Mg, Cecchini, S., Cindolo, F., Collazuol, G., Conti, E., Dal Corso, F., Delogu, C., De Rosa, G., Falcone, A., Gola, A., Jollet, C., Klicek, B., Kudenko, Y., Laveder, M., Longhin, A., Ludovici, L., Lutsenko, E., Magaletti, L., Mandrioli, G., Margotti, A., Mascagna, Mauri, N., Meazza, L., Meregaglia, A., Mezzetto, M., Paoloni, A., Pari, M., Parozzi, E., Pasqualini, L., Paternoster, G., Patrizii, L., Pozzato, M., Prest, M., Pupilli, F., Radicioni, E., Riccio, C., Ruggeri, A. C., Scian, C., Sirri, G., Stipcevic, M., Tenti, M., Terranova, F., Torti, M., Vallazza, E., Votano, L.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A prototype for the instrumented decay tunnel of ENUBET was tested in 2018 at the CERN East Area facility with charged particles up to 5 GeV. This detector is a longitudinal sampling calorimeter with lateral scintillation light readout. The calorimeter was equipped by an additional "t(0)-layer" for timing and photon discrimination. The performance of this detector in terms of electron energy resolution, linearity, response to muons and hadron showers are presented in this paper and compared with simulation. The t(0)-layer was studied both in standalone mode using pion charge exchange and in combined mode with the calorimeter to assess the light yield and the 1 mip/2 mip separation capability. We demonstrate that this system fulfills the requirements for neutrino physics applications and discuss performance and additional improvements.
ISSN:1748-0221
1748-0221
DOI:10.1088/1748-0221/15/08/P08001