Impact of fuel quality and burner capacity on the performance of wood pellet stove
Pellet stoves may play an important role in Serbia in the future when fossil fuel fired conventional heating appliances are replaced by more efficient and environmentally friendly devices. Experimental investigation was conducted in order to examine the influence of wood pellet quality, as well as b...
Gespeichert in:
Veröffentlicht in: | Thermal science 2015, Vol.19 (5), p.1855-1866 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Pellet stoves may play an important role in Serbia in the future when fossil
fuel fired conventional heating appliances are replaced by more efficient and
environmentally friendly devices. Experimental investigation was conducted in
order to examine the influence of wood pellet quality, as well as burner
capacity (6, 8 and 10 kW), used in the same stove configuration, on the
performance of pellet stove with declared nameplate capacity of 8 kW. The
results obtained showed that in case of nominal load and combustion of
pellets recommended by the stove manufacturer, stove efficiency of 80.03% was
achieved. The use of lower quality pellet caused additional 1.13 kW reduction
in heat output in case of nominal load and 0.63 kW in case of reduced load.
This was attributed to less favourable properties and lower bulk and particle
density of lower quality pellet. The use of different burner capacity has
shown to have little effect on heat output and efficiency of the stove when
pre-set values in the control system of the stove were not altered. It is
concluded that replacement of the burner only is not sufficient to
increase/decrease the declared capacity of the same stove configuration,
meaning that additional measures are necessary. These measures include a new
set up of the stove control system, which needs to be properly adjusted for
each alteration in stove configuration. Without the adjustment mentioned,
declared capacity of the stove cannot be altered, while its CO emission shall
be considerably increased.
nema |
---|---|
ISSN: | 0354-9836 2334-7163 |
DOI: | 10.2298/TSCI150310082P |