Gain Factor of the Pelletized Cold Neutron Moderator at 22 K

The current results of operation of the first CM1 cryogenic moderator in the direction of neutron beams 7, 8, 10, and 11 at the power of IBR-2 with a new cryogenic system are presented in the paper. A new cryogenic system allowed to reduce the temperature of the working mixture in the chamber of the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Surface investigation, x-ray, synchrotron and neutron techniques x-ray, synchrotron and neutron techniques, 2020-05, Vol.14 (3), p.434-436
Hauptverfasser: Bulavin, M. V., Belyakov, A. A., Verkhoglyadov, A. E., Kulikov, S. A., Mukhin, K. A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The current results of operation of the first CM1 cryogenic moderator in the direction of neutron beams 7, 8, 10, and 11 at the power of IBR-2 with a new cryogenic system are presented in the paper. A new cryogenic system allowed to reduce the temperature of the working mixture in the chamber of the CM1 moderator when operating at a reactor power of 2 MW by 10 K to ~22–23 K which made possible to acquire gain in the intensity of cold neutrons ~15–20%.
ISSN:1027-4510
1819-7094
DOI:10.1134/S1027451020030040