Gain Factor of the Pelletized Cold Neutron Moderator at 22 K
The current results of operation of the first CM1 cryogenic moderator in the direction of neutron beams 7, 8, 10, and 11 at the power of IBR-2 with a new cryogenic system are presented in the paper. A new cryogenic system allowed to reduce the temperature of the working mixture in the chamber of the...
Gespeichert in:
Veröffentlicht in: | Surface investigation, x-ray, synchrotron and neutron techniques x-ray, synchrotron and neutron techniques, 2020-05, Vol.14 (3), p.434-436 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The current results of operation of the first CM1 cryogenic moderator in the direction of neutron beams 7, 8, 10, and 11 at the power of IBR-2 with a new cryogenic system are presented in the paper. A new cryogenic system allowed to reduce the temperature of the working mixture in the chamber of the CM1 moderator when operating at a reactor power of 2 MW by 10 K to ~22–23 K which made possible to acquire gain in the intensity of cold neutrons ~15–20%. |
---|---|
ISSN: | 1027-4510 1819-7094 |
DOI: | 10.1134/S1027451020030040 |