Synthesis of silver nanoparticles decorated on reduced graphene oxide nanosheets and their electrochemical sensing towards hazardous 4-nitrophenol
In this study, an electrochemical sensor for the detection of 4-Nitrophenol (referred to as 4-NP) was developed based on templated silver nanoparticles (AgNPs) on reduced graphene oxide (rGO) nanosheets (Ag-rGO) and utilized as an electrocatalyst. It was found that the resulting composite exhibits e...
Gespeichert in:
Veröffentlicht in: | Journal of materials science. Materials in electronics 2020-07, Vol.31 (14), p.11927-11937 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In this study, an electrochemical sensor for the detection of 4-Nitrophenol (referred to as 4-NP) was developed based on templated silver nanoparticles (AgNPs) on reduced graphene oxide (rGO) nanosheets (Ag-rGO) and utilized as an electrocatalyst. It was found that the resulting composite exhibits enhanced catalytic activity towards the reduction of 4-NP. The cubic shaped AgNPs templated on rGO nanosheets has been successfully fabricated by a chemical reduction method using sodium borohydride (NaBH
4
), and it was well characterized through morphological and electrochemical techniques: Ultraviolet–Visible spectroscopy (UV -Vis), scanning electron microscopy (SEM) equipped with energy-dispersive spectroscopy (SEM–EDS), transmission electron microscopy (TEM), X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FT-IR), cyclic voltammetry (CV), and chronoamperometry. The obtained results revealed that the AgNPs scattered on rGO sheets are spherical in shape, and it’s estimated to be a dimension of ~ 60 nm in size. The prepared crystalline Ag-rGO nano sheets were further applied as an electrode material for the electrochemical examination with three electrode system to sense the hazardous material 4-NP in PBS. The electrochemical studies were conducted through CV under the condition of bare and coated electrode (Ag-rGO/GCE) with influence of concentration (4-NP from 2 to 150 mM), scan rate, reproducibility (RSD-2.87%) and stability test (4-NP-20 µM) were examined. The data reveal that the Ag-rGO/GCE exhibit highly reproducible and sustainable for the reduction of toxic 4-NP. The chronoamperometry study for current and time response was also studied at two different potentials (− 0.3 V & − 0.6 V), respectively. |
---|---|
ISSN: | 0957-4522 1573-482X |
DOI: | 10.1007/s10854-020-03747-3 |