Ultrasonic Technique for Assessment of the Rim Tightness of Hydro Generator Rotor
At the hydroelectric unit No. 11 of the Nizhnekamsk hydroelectric power plant, the filling wedges of a rotor were investigated by ultrasound in the free state, after “cold” tight shrinking, after “hot” tight shrinking, and after 3000 and 8000 hours of operation. The ability to evaluate the rim tight...
Gespeichert in:
Veröffentlicht in: | Power technology and engineering 2020, Vol.53 (6), p.687-689 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | At the hydroelectric unit No. 11 of the Nizhnekamsk hydroelectric power plant, the filling wedges of a rotor were investigated by ultrasound in the free state, after “cold” tight shrinking, after “hot” tight shrinking, and after 3000 and 8000 hours of operation. The ability to evaluate the rim tightness of the rotor based on data on the redistribution of compression efforts in the wedges is demonstrated. |
---|---|