Production of 99Mo/99mTc by photonuclear reaction using a natMoO3 target
Amount estimation of production of 99 Mo required for medical applications was carried out by utilizing an electron linear accelerator with 30 g of nat MoO 3 target, and 15.10 MBq of 99 Mo was obtained after 9.5 min of irradiation with bremsstrahlung photons by a 35 MeV-80 μA electron beam. Requirem...
Gespeichert in:
Veröffentlicht in: | Journal of radioanalytical and nuclear chemistry 2020, Vol.324 (2), p.681-686 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Amount estimation of production of
99
Mo required for medical applications was carried out by utilizing an electron linear accelerator with 30 g of
nat
MoO
3
target, and 15.10 MBq of
99
Mo was obtained after 9.5 min of irradiation with bremsstrahlung photons by a 35 MeV-80 μA electron beam. Requirements for further scaled-up production with
100
MoO
3
target (100 g, φ20 mm × t30 mm) were analyzed using Monte Carlo simulation. It was found that it had to be irradiated with 20 h of bremsstrahlung photons by a 35 MeV-1 mA electron beam to produce 1340 GBq of
99
Mo. |
---|---|