New Triazole and Isoxazole Compounds as Corrosion Inhibitors for Cu-Ni (90/10) Alloy and Galvanized Steel Substrates

Three organic compounds containing azole rings 1-benzyl-4-phenyl-1H-1,2,3-triazole (I 1 ), 5-phenyl-3-propylisoxazole (I 2 ), and 3,5-diphenylisoxazole (I 3 ) were synthesized and characterized as corrosion inhibitors on galvanized steel and copper-nickel (Cu-Ni, 90/10) substrates. The three tested...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Metallurgical and materials transactions. A, Physical metallurgy and materials science Physical metallurgy and materials science, 2020-04, Vol.51 (4), p.1822-1845
Hauptverfasser: Domínguez-Crespo, M. A., Zepeda-Vallejo, L. Gerardo, Torres-Huerta, A. M., Brachetti-Sibaja, S. B., Palma-Ramírez, D., Rodríguez-Salazar, A. E., Ontiveros-de la Torre, D. E.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Three organic compounds containing azole rings 1-benzyl-4-phenyl-1H-1,2,3-triazole (I 1 ), 5-phenyl-3-propylisoxazole (I 2 ), and 3,5-diphenylisoxazole (I 3 ) were synthesized and characterized as corrosion inhibitors on galvanized steel and copper-nickel (Cu-Ni, 90/10) substrates. The three tested azole inhibitors acted as corrosion inhibitors on galvanized steel in the presence of real cooling water used as electrolyte. Electrochemical performance indicated that the presence of heteroatoms, such as N and O, with free pair electrons, the chain length, and the aromatic ring plays an important role in the capacity to inhibit corrosion of galvanized steel. 3,5-diphenylisoxazole (I 3 ) has the best inhibition activity with j corr of 2.04 × 10 −7 (5 ppm), 7.57 × 10 −8 (10 ppm), and 1.73 × 10 −8 (20 ppm) A cm −2 , followed by compounds I 1 and I 2 . The synthesized compounds are comparable or even higher than the electrochemical performance of commercial inhibitor tolyltriazole (TTA, j corr = 3.06 × 10 −8 A cm −2 ). Conversely, for Cu-Ni (90/10) substrates, commercial TTA with 20 ppm displayed the lowest corrosion current densities ( j corr = 3.20 × 10 −8 A cm −2 ) through a characteristic anodic pseudo-passivation; however, pits were observed after ~550 mV Ag/AgCl . In contrast, the synthesized compounds tended to suppress anodic copper dissolution at positive potentials but, in the best case, displayed greater corrosion rates I 3 (1.463 mils per year (MPY)), I 2 (1.515 MPY), and I 1 (0.677 MPY) in comparison with TTA (0.091 MPY). The low inhibition efficiency (IE) of synthesized compounds is correlated to the weak absorption on the copper surface.
ISSN:1073-5623
1543-1940
DOI:10.1007/s11661-019-05615-0