Self-assembly of super-hydrophobic PMMA microspheres on silicon wafer as MALDI-MS chip for rapid quantification of peptides

•A novel super-hydrophobic structured-PMMA chip for MALDI-MS is prepared by a simple self-assembly method.•The MALDI-MS detection reproducibility and sensitivity are highly improved with this chip compared to the conventional steel target.•Different peptides can be quantified in a broad range with t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Sensors and actuators. B, Chemical Chemical, 2020-03, Vol.306, p.127573, Article 127573
Hauptverfasser: Dou, Shuzhen, Li, Ning, Wang, Xueyun, Zhu, Qunyan, Wang, Zhongshun, Lu, Nan
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:•A novel super-hydrophobic structured-PMMA chip for MALDI-MS is prepared by a simple self-assembly method.•The MALDI-MS detection reproducibility and sensitivity are highly improved with this chip compared to the conventional steel target.•Different peptides can be quantified in a broad range with this chip by MALDI-MS without internal standard.•Different practical peptides samples can be quantified in a broad range with this chip without internal standard by MALDI-MS. Rapid quantification of peptides by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is a challenge. Herein, we prepared a super-hydrophobic poly(methyl methacrylate) (PMMA) structured chip for quantifying peptides without internal standard by improving the detection reproducibility and sensitivity. The chip was formed by PMMA microspheres through a self-assembly method. As a good adsorbent of peptides, PMMA microspheres make peptides distributed uniformly on the chip, resulting in the elimination of the coffee ring effect and the homogeneous co-crystallization of peptides/matrix. The relative standard deviations (∼ 10 %) and coefficients of determination (∼ 0.99) are satisfactory when detecting 3 standard peptides, which show that the chip is applicable for rapid quantification of peptides. The limit of detection is improved by 1000-fold on this chip compared with conventional steel target because of the enrichment of the super-hydrophobicity. It can be concluded that the detection reproducibility and sensitivity are significantly improved by the super-hydrophobic structured-PMMA chip. The applicability of the chip for practical samples is demonstrated by quantifying bacitracin A in milk extract and bradykinin1-7 in serum with good linearities. The structured-PMMA chips exhibit competitive advantages for quantitative analysis of peptides, which have a great potential for proteomic research.
ISSN:0925-4005
1873-3077
DOI:10.1016/j.snb.2019.127573