Collapse analysis of regular and irregular tall steel moment frames under fire loading

Summary This study is carried out to evaluate the progressive collapse of steel buildings under fire event. To this end, a 15‐story steel structure with moment‐resisting system and composite floors is considered. The effects of various parameters such as beam section size, gravity load ratio, vertic...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The structural design of tall and special buildings 2020-02, Vol.29 (3), p.n/a
Hauptverfasser: Heshmati, Mahdi, Aghakouchak, Ali Akbar
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Summary This study is carried out to evaluate the progressive collapse of steel buildings under fire event. To this end, a 15‐story steel structure with moment‐resisting system and composite floors is considered. The effects of various parameters such as beam section size, gravity load ratio, vertical irregularity of resisting system, and location of fire compartments on collapse modes are investigated numerically. Different temperature‐time curves are defined across the composite floors according to the Eurocode 4. It is found that local collapse of the frames at the ground floor fire is triggered by the buckling of the interior heated columns at approximately 540°C. The redistributed loads by floors delay the global collapse at least 45 min. Increasing gravity loads accelerates the global collapse of the frames significantly. The heated columns of the middle floor buckle at higher temperature compared to the ground floor heated columns and no global collapse occur due to this scenario. In general, the potential of collapse of the regular and irregular frame due to fire in the edge bay is higher compared to the fire in the middle bay. It is also found that the local and global collapse of regular frames occur earlier than irregular frames.
ISSN:1541-7794
1541-7808
DOI:10.1002/tal.1696