Study on the Design of a New Heatsink Cooling System for Thermoelectric Dehumidifier

A thermoelectric dehumidifier may be built smaller than a compressor type dehumidifier of the same capacity; however, its efficiency is lower. This study proposes a new heat dissipation structure to improve the performance of a thermoelectric module (TEM) for the dehumidifier. The new structure ensu...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International journal of precision engineering and manufacturing 2020, Vol.21 (1), p.75-80
Hauptverfasser: Im, Dam-Hyeok, Kwon, Hyo-Chan, Kim, Kwang-Joon, Kim, Kwon-Hee
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A thermoelectric dehumidifier may be built smaller than a compressor type dehumidifier of the same capacity; however, its efficiency is lower. This study proposes a new heat dissipation structure to improve the performance of a thermoelectric module (TEM) for the dehumidifier. The new structure ensures that cooled and dehumidified air flows through one or more holes inside the heatsink base. The design parameters selected for the orthogonal array experiments are existence of the holes, drive voltage of the TEM, air inflow rate, and the cooling fan position. Experimental results reveal that the air flow through the holes has the greatest effect on dehumidification efficiency. Through subsequent experiments, the number of holes and drive voltage of TEM required to maximize dehumidification capacity and coefficient of performance are obtained.
ISSN:2234-7593
2005-4602
DOI:10.1007/s12541-019-00259-x