A study on the corrosion behavior of nickel in ClF3 gas

[Display omitted] •The kinetic corrosion behavior of Ni metal in ClF3 changed markedly at the point of 823 K.•The corrosion material was confirmed as NiF2 using XRD and XPS results.•The recommended maximum temperature to use Ni in 0.1 MPa ClF3 gas was estimated to be 748 K. The reaction mechanism be...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of fluorine chemistry 2019-08, Vol.224, p.73-79
Hauptverfasser: Kim, Jae-Ho, Namie, Masanari, Yonezawa, Susumu
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:[Display omitted] •The kinetic corrosion behavior of Ni metal in ClF3 changed markedly at the point of 823 K.•The corrosion material was confirmed as NiF2 using XRD and XPS results.•The recommended maximum temperature to use Ni in 0.1 MPa ClF3 gas was estimated to be 748 K. The reaction mechanism between 0.1 MPa ClF3 gas and Ni was investigated in the temperature range of 473–873 K for 0–120 h. The kinetic corrosion behavior of Ni metal under 0.1 MPa ClF3 gas changed markedly at the point of 823 K. The reaction temperature is the most important factor in the corrosion behavior of metals with oxidative gas. As a result, the recommended maximum temperature to use Ni in 0.1 MPa ClF3 gas was estimated to be 748 K.
ISSN:0022-1139
1873-3328
DOI:10.1016/j.jfluchem.2019.05.005