Comparison of Swiffer Wipes and Conventional Drag Swab Methods for the Recovery of Salmonella in Swine Production Systems

The main goal of this study was to assess the efficacy of Swiffer wipes in comparison to conventional drag swabs for the recovery of Salmonella. A total of 800 samples (400 Swiffer wipes and 400 drag swabs) were aseptically collected from randomly selected swine barns before disinfection with specif...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of food protection 2009, Vol.72 (1), p.142-146
Hauptverfasser: MOLLA ZEWDE, Bayleyegn, ROBBINS, Rebecca, ABLEY, Melanie J, HOUSE, Brandon, MORGAN MORROW, W. E, GEBREYES, Wondwossen A
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The main goal of this study was to assess the efficacy of Swiffer wipes in comparison to conventional drag swabs for the recovery of Salmonella. A total of 800 samples (400 Swiffer wipes and 400 drag swabs) were aseptically collected from randomly selected swine barns before disinfection with specific biocides and within 2 h after disinfection. From each barn, 10 samples of each swab type and negative controls were collected. Salmonellae were isolated from 43 (10.8%) of 400 drag swabs and 34 (8.5%) of 400 Swiffer wipes. There was a significant reduction in Salmonella postdisinfection as identified with both sampling procedures irrespective of the type of biocide used (P < 0.05). With the drag swabs, salmonellae were detected in 15% of the samples before disinfection versus 6.5% after disinfection, whereas with the Swiffer wipes, 13 and 4% of the samples were positive pre- and postdisinfection, respectively. Of the total 720 fecal samples collected from pigs placed in the disinfected barns, 132 (18.3%) were Salmonella positive. About 65 and 98% of the Salmonella isolates from swine barns and fecal samples, respectively, were resistant to one or more of the antimicrobials tested. Multidrug resistance was found in 35.7% of the isolates from barn swabs and 56.4% of the isolates from fecal samples. Results of this study suggest that the conventional drag swab method results in better recovery of Salmonella than does the Swiffer wipe method and thus could be a useful sampling method in monitoring Salmonella. Pentaresistant Salmonella (mainly R-type ACSSuT) was more common in fecal samples than in environmental samples.
ISSN:0362-028X
1944-9097
DOI:10.4315/0362-028X-72.1.142