Distribution of pressure gradients along hepatic vasculature

A study tested the hypothesis that the hepatic sinusoidal pressure is virtually identical to the portal venous pressure (Ppv) or the abdominal vena caval pressure (Pavc). Data indicate that sinusoidal pressures are not closely similar to either the Ppv or the Pavc.

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:American journal of physiology. Heart and circulatory physiology 1997-06, Vol.41 (6), p.H2826-H2832
Hauptverfasser: MAASS-MORENO, R, ROTHE, C. F
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A study tested the hypothesis that the hepatic sinusoidal pressure is virtually identical to the portal venous pressure (Ppv) or the abdominal vena caval pressure (Pavc). Data indicate that sinusoidal pressures are not closely similar to either the Ppv or the Pavc.