Experiments on Continuous Unbonded Post-Tensioned Beams with 2400 MPa (350 ksi) Strands

Experiments on seven two-span unbonded post-tensioned beams were conducted under four-point static loading conditions. Variables considered included: strand type (nominal tensile strength); tendon drape (height of tendon profile); and magnitude of prestress. Experimental emphasis was placed on the a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:ACI structural journal 2019-09, Vol.116 (5), p.125-136
Hauptverfasser: Kim, Kyungmin, Kang, Thomas H.-K.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Experiments on seven two-span unbonded post-tensioned beams were conducted under four-point static loading conditions. Variables considered included: strand type (nominal tensile strength); tendon drape (height of tendon profile); and magnitude of prestress. Experimental emphasis was placed on the applicability of using higher-strength 2400 MPa (350 ksi) strands instead of ordinary 1860 MPa (270 ksi) strands in unbonded post-tensioned beam members. Observed results revealed that specimens with 2400 MPa (350 ksi) tensile strength 15.2 mm (0.6 in.) diameter strands developed equivalent tendon stress increment, load-carrying capacity, and flexural ductility while at the ultimate limit state having earlier and wider plastic hinge.
ISSN:0889-3241
1944-7361