Compressive Behavior of Brick Masonry Columns Confined with Steel-Reinforced Grout Jackets

AbstractIn this study, a new type of composite comprised of steel cords embedded in a mortar matrix—referred to as steel-reinforced grout (SRG)—is explored for use in the confinement of masonry columns. This paper presents the results of an experimental study carried out to understand the behavior o...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of composites for construction 2019-10, Vol.23 (5)
Hauptverfasser: Sneed, Lesley H, Baietti, Giulia, Fraioli, Giacomo, Carloni, Christian
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:AbstractIn this study, a new type of composite comprised of steel cords embedded in a mortar matrix—referred to as steel-reinforced grout (SRG)—is explored for use in the confinement of masonry columns. This paper presents the results of an experimental study carried out to understand the behavior of solid clay brick masonry columns confined by single-layer SRG jackets. Thirty-one confined and three unconfined columns with a square cross-section were tested to failure under a monotonic concentric compressive load. Test parameters considered were the SRG matrix type, column corner condition, and steel cord sheet density (i.e., steel cord spacing) in the SRG jacket. SRG confinement improved the compressive strength, ultimate strain, and energy absorption of masonry columns relative to the unconfined condition. Models from the literature for FRP-confined masonry were examined for their applicability to predict the strength increase from the SRG jacket, with certain models predicting the confined compressive strength within 9% of the test values.
ISSN:1090-0268
1943-5614
1943-5614
DOI:10.1061/(ASCE)CC.1943-5614.0000963