Point-of-need detection of microcystin-LR using a smartphone-controlled electrochemical analyzer
•A portable and wireless point-of-need detection system for microcystin-LR (MC-LR) quantitation was developed and validated.•The detection system consisted of three main parts: screen printed carbon electrodes (SPCEs), smartphone-controlled electrochemical analyzer (SCEA), and Android's smartph...
Gespeichert in:
Veröffentlicht in: | Sensors and actuators. B, Chemical Chemical, 2019-09, Vol.294, p.132-140 |
---|---|
Hauptverfasser: | , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | •A portable and wireless point-of-need detection system for microcystin-LR (MC-LR) quantitation was developed and validated.•The detection system consisted of three main parts: screen printed carbon electrodes (SPCEs), smartphone-controlled electrochemical analyzer (SCEA), and Android's smartphone.•A spatiotemporal mapping of MC-LR field detection was conducted to further validate the feasibility of the SCEA for on-site screening.
The development of rapid and in situ detection method for microcystin-LR (MC-LR) with portable, reliable, and easy to use devices are highly demanded, but it is still deficient. In this study, a portable and wireless point-of-need detection system for microcystin-LR (MC-LR) quantitation was developed and validated. The whole system consisted of three main parts: screen printed carbon electrodes (SPCEs), smartphone-controlled electrochemical analyzer (SCEA), and Android's smartphone. The SCEA was a homemade ARM STM32 microcontroller-based electrochemical analyzer, which have similar performance compared with a commercially available electrochemical workstation. A smartphone installed with a user-friendly application was employed to control the analyzer, receive and analyze data, and display detection results in real-time. This system can accurately quantitate MC-LR in the range of 0.001–100 μg/L with a detection limit of 0.00011 μg/L, and the results were consistent with LC–MS/MS. In addition, a preliminary MC-LR contamination map was generated using this smartphone-based platform by measuring water samples at 6 reservoirs located in Pearl River Delta (Guangdong Province, China). The cost-effective, reliable and easy-to-use smartphone-based detection system reported here can facilitate active toxicant screening to guarantee the safety of the drinking water, particularly in resource-limited area. |
---|---|
ISSN: | 0925-4005 1873-3077 |
DOI: | 10.1016/j.snb.2019.05.028 |