Paper-based electroanalytical strip for user-friendly blood glutathione detection
•Blood glutathione is reagentlessly detected.•Paper-based strips allow to measure 5 μL of sample only.•Blood does not interfere with electrochemical measures.•Filter paper blocks gross impurities from blood.•Electrochemical strips allow for de-centralized tests. Paper-based devices are always more g...
Gespeichert in:
Veröffentlicht in: | Sensors and actuators. B, Chemical Chemical, 2019-09, Vol.294, p.291-297 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | •Blood glutathione is reagentlessly detected.•Paper-based strips allow to measure 5 μL of sample only.•Blood does not interfere with electrochemical measures.•Filter paper blocks gross impurities from blood.•Electrochemical strips allow for de-centralized tests.
Paper-based devices are always more gaining a relevant position in the field of sensors. The continuous demand for affordable, simple, sustainable, and portable devices, is making paper as the ideal basis towards the realization of analytical tools for the easy self-testing. In this work, we demonstrate, for the first time, the development of a disposable paper-based printed electroanalytical strip for reliable, rapid, and high-throughput detection of glutathione in blood. The detection is based on the thiol-disulfide exchange reaction, which produces a detectable compound easily oxidizable at a Prussian Blue/carbon black nanocomposite involving a favorable low-interference overpotential. This nanocomposite is mixed within a carbon-based conductive ink and successively screen-printed onto a wax-patterned filter paper. The employment of paper provides a reagent-free device, as a consequence of the reagents pre-loading within the testing area. After the experimental conditions have been optimized, glutathione has been detected up to 10 mM, with a detection limit of 60 μM, and a sensitivity of (0.102 ± 0.005) μA/mM. This sensor showed satisfactory repeatability (relative standard deviation equal to 10%, for detection of glutathione 1 mM), especially by considering the hand-made manufacturing process. The “real-world” applicability of this strip has been evaluated by quantifying blood glutathione at physiological levels and by recovery studies achieving satisfactory values. |
---|---|
ISSN: | 0925-4005 1873-3077 |
DOI: | 10.1016/j.snb.2019.02.082 |