Validity of fan-beam dual-energy X-ray absorptiometry for measuring fat-free mass and leg muscle mass
1 Epidemiology, Demography and Biometry Program, National Institute on Aging, Bethesda, Maryland 20892; 2 Institute for Research in Extramural Medicine, Faculty of Medicine, Vrije Universiteit, 1081 BT Amsterdam, The Netherlands; 3 Department of Radiology, University of California, San Francisco,...
Gespeichert in:
Veröffentlicht in: | Journal of applied physiology (1985) 1999-10, Vol.87 (4), p.1513-1520 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | 1 Epidemiology, Demography and
Biometry Program, National Institute on Aging, Bethesda, Maryland
20892; 2 Institute for Research in
Extramural Medicine, Faculty of Medicine, Vrije Universiteit, 1081 BT Amsterdam, The Netherlands;
3 Department of Radiology,
University of California, San Francisco, California 94105; and
4 Department of Epidemiology,
University of Pittsburgh, Pittsburgh, Pennsylvania 15261
The aim of the study was to examine the accuracy
of fan-beam dual-energy X-ray absorptiometry (DEXA) for measuring total
body fat-free mass (FFM) and leg muscle mass (MM) in elderly persons. Participants were 60 men and women aged 70-79 yr and with a body mass index of 17.5-39.8
kg/m 2 . FFM and MM at four leg
regions were measured by using DEXA (Hologic 4500A, v8.21). A
four-compartment body composition model (4C) and multislice computed
tomography (CT) of the legs were used as the criterion methods for FFM
and MM, respectively. FFM by DEXA was positively associated with FFM by
4C ( R 2 = 0.98, SE
of estimate = 1.6 kg). FFM by DEXA was higher [53.5 ± 12.0 (SD) kg] than FFM by 4C (51.6 ± 11.9 kg;
P |
---|---|
ISSN: | 8750-7587 1522-1601 |
DOI: | 10.1152/jappl.1999.87.4.1513 |