Multi-matrix opto-electronic system for measuring deformation of the millimeter range radiotelescope elements
A novel optical instrument is proposed and studied to measure the deformation of each connection point for a mirror, which includes 24 multi-matrix base units and can be used in millimeter-scale signal reflection systems. Experimental investigations reveal that the error of measurement is σ =8.7×10...
Gespeichert in:
Veröffentlicht in: | Optoelectronics letters 2019-03, Vol.15 (2), p.144-146 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A novel optical instrument is proposed and studied to measure the deformation of each connection point for a mirror, which includes 24 multi-matrix base units and can be used in millimeter-scale signal reflection systems. Experimental investigations reveal that the error of measurement is
σ
=8.7×10
−3
mm at a distance of 5 500 mm, which allows to measure the linear deformation of a radiotelescope with the mirror diameter of 70 m. |
---|---|