Campus Drinking Water Supply System Performance Analysis Universitas Gadjah Mada of Yogyakarta

The decent quality, quantity, and continuity of Drinking Water Supply System (DWSS) are needed to support the activities of a campus. Universitas Gadjah Mada drinking water supply system (UGM-DWSS) provides 49 Water Fountains (WF) and 12 Water Dispensers (WD) to support daily activities for all the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied Mechanics and Materials 2018-05, Vol.881, p.64-69
Hauptverfasser: Supraba, Intan, Kamulyan, Budi, Triatmadja, Radianta, Setiawan, Teguh
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 69
container_issue
container_start_page 64
container_title Applied Mechanics and Materials
container_volume 881
creator Supraba, Intan
Kamulyan, Budi
Triatmadja, Radianta
Setiawan, Teguh
description The decent quality, quantity, and continuity of Drinking Water Supply System (DWSS) are needed to support the activities of a campus. Universitas Gadjah Mada drinking water supply system (UGM-DWSS) provides 49 Water Fountains (WF) and 12 Water Dispensers (WD) to support daily activities for all the campus community. This research aimed at figuring out the performance of the existing UGM-DWSS against the current service pipeline distribution network so that the technical condition of the pipes’ pressure, the water consumption’s discharge, and the pumps’ use can be identified. The method used for analyzing is by implementing simulating the network performance using WaterNet program version 2.2 by which pipes network and its facilities performance including optimization of pipe diameter can be described. The simulation indicated that there was 80% idle capacity of the available water capacity. It is uneconomical to make any changes to the existing pipes’ condition considering the very high cost of the pipeline construction. Therefore, pump replacement was considered more feasible optimization approach. To obtain the optimal results, the pump should be replaced with 4 m3/hours capacity with 20 meters pump design head.
doi_str_mv 10.4028/www.scientific.net/AMM.881.64
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2199197995</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2199197995</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1914-a2d50352b65b9bf9e85ff0ae5bbc6c3cd7bc58ce9427611d54c790588892dca03</originalsourceid><addsrcrecordid>eNqNkE9P2zAYxi0G0qDjO1hCOya1HduxD9NUdRtMagUSQ4gL1hvHKS5tEux0Vb49HkXiutN7eP68j34IfaUk54Sp6X6_z6P1rh18423eumE6Wy5zpWgu-RE6pVKyrOSKfULnulQFKURJmdTq-E0jmS4K-RmdxbgmRHLK1Sl6nMO230X8I_j22bcrfA-DC_h21_ebEd-OcXBbfONC04UttNbhWQubMfqI71r_14XoB4j4Euo1POEl1IC7Bj90qxGeIQzwBZ00sInu_P1O0N2vn3_mV9ni-vL3fLbILNWUZ8BqkdaySopKV412SjQNASeqykpb2LqsrFDWac5KSWktuC01EUopzWoLpJigi0NvH7qXnYuDWXe7kKZGw6jWVJdai-T6dnDZ0MUYXGP64LcQRkOJ-YfYJMTmA7FJiE1CbBJiI3nKfz_khwBtImOfPt78X8MrGiCL3g</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2199197995</pqid></control><display><type>article</type><title>Campus Drinking Water Supply System Performance Analysis Universitas Gadjah Mada of Yogyakarta</title><source>Scientific.net Journals</source><creator>Supraba, Intan ; Kamulyan, Budi ; Triatmadja, Radianta ; Setiawan, Teguh</creator><creatorcontrib>Supraba, Intan ; Kamulyan, Budi ; Triatmadja, Radianta ; Setiawan, Teguh</creatorcontrib><description>The decent quality, quantity, and continuity of Drinking Water Supply System (DWSS) are needed to support the activities of a campus. Universitas Gadjah Mada drinking water supply system (UGM-DWSS) provides 49 Water Fountains (WF) and 12 Water Dispensers (WD) to support daily activities for all the campus community. This research aimed at figuring out the performance of the existing UGM-DWSS against the current service pipeline distribution network so that the technical condition of the pipes’ pressure, the water consumption’s discharge, and the pumps’ use can be identified. The method used for analyzing is by implementing simulating the network performance using WaterNet program version 2.2 by which pipes network and its facilities performance including optimization of pipe diameter can be described. The simulation indicated that there was 80% idle capacity of the available water capacity. It is uneconomical to make any changes to the existing pipes’ condition considering the very high cost of the pipeline construction. Therefore, pump replacement was considered more feasible optimization approach. To obtain the optimal results, the pump should be replaced with 4 m3/hours capacity with 20 meters pump design head.</description><identifier>ISSN: 1660-9336</identifier><identifier>ISSN: 1662-7482</identifier><identifier>ISBN: 9783035712698</identifier><identifier>ISBN: 3035712697</identifier><identifier>EISSN: 1662-7482</identifier><identifier>DOI: 10.4028/www.scientific.net/AMM.881.64</identifier><language>eng</language><publisher>Zurich: Trans Tech Publications Ltd</publisher><subject>Construction costs ; Current distribution ; Dispensers ; Distribution management ; Drinking water ; Measuring instruments ; Optimization ; Pipes ; Water consumption ; Water discharge ; Water shortages ; Water supply</subject><ispartof>Applied Mechanics and Materials, 2018-05, Vol.881, p.64-69</ispartof><rights>2018 Trans Tech Publications Ltd</rights><rights>Copyright Trans Tech Publications Ltd. May 2018</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c1914-a2d50352b65b9bf9e85ff0ae5bbc6c3cd7bc58ce9427611d54c790588892dca03</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttps://www.scientific.net/Image/TitleCover/4619?width=600</thumbnail><link.rule.ids>314,778,782,27907,27908</link.rule.ids></links><search><creatorcontrib>Supraba, Intan</creatorcontrib><creatorcontrib>Kamulyan, Budi</creatorcontrib><creatorcontrib>Triatmadja, Radianta</creatorcontrib><creatorcontrib>Setiawan, Teguh</creatorcontrib><title>Campus Drinking Water Supply System Performance Analysis Universitas Gadjah Mada of Yogyakarta</title><title>Applied Mechanics and Materials</title><description>The decent quality, quantity, and continuity of Drinking Water Supply System (DWSS) are needed to support the activities of a campus. Universitas Gadjah Mada drinking water supply system (UGM-DWSS) provides 49 Water Fountains (WF) and 12 Water Dispensers (WD) to support daily activities for all the campus community. This research aimed at figuring out the performance of the existing UGM-DWSS against the current service pipeline distribution network so that the technical condition of the pipes’ pressure, the water consumption’s discharge, and the pumps’ use can be identified. The method used for analyzing is by implementing simulating the network performance using WaterNet program version 2.2 by which pipes network and its facilities performance including optimization of pipe diameter can be described. The simulation indicated that there was 80% idle capacity of the available water capacity. It is uneconomical to make any changes to the existing pipes’ condition considering the very high cost of the pipeline construction. Therefore, pump replacement was considered more feasible optimization approach. To obtain the optimal results, the pump should be replaced with 4 m3/hours capacity with 20 meters pump design head.</description><subject>Construction costs</subject><subject>Current distribution</subject><subject>Dispensers</subject><subject>Distribution management</subject><subject>Drinking water</subject><subject>Measuring instruments</subject><subject>Optimization</subject><subject>Pipes</subject><subject>Water consumption</subject><subject>Water discharge</subject><subject>Water shortages</subject><subject>Water supply</subject><issn>1660-9336</issn><issn>1662-7482</issn><issn>1662-7482</issn><isbn>9783035712698</isbn><isbn>3035712697</isbn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><recordid>eNqNkE9P2zAYxi0G0qDjO1hCOya1HduxD9NUdRtMagUSQ4gL1hvHKS5tEux0Vb49HkXiutN7eP68j34IfaUk54Sp6X6_z6P1rh18423eumE6Wy5zpWgu-RE6pVKyrOSKfULnulQFKURJmdTq-E0jmS4K-RmdxbgmRHLK1Sl6nMO230X8I_j22bcrfA-DC_h21_ebEd-OcXBbfONC04UttNbhWQubMfqI71r_14XoB4j4Euo1POEl1IC7Bj90qxGeIQzwBZ00sInu_P1O0N2vn3_mV9ni-vL3fLbILNWUZ8BqkdaySopKV412SjQNASeqykpb2LqsrFDWac5KSWktuC01EUopzWoLpJigi0NvH7qXnYuDWXe7kKZGw6jWVJdai-T6dnDZ0MUYXGP64LcQRkOJ-YfYJMTmA7FJiE1CbBJiI3nKfz_khwBtImOfPt78X8MrGiCL3g</recordid><startdate>20180501</startdate><enddate>20180501</enddate><creator>Supraba, Intan</creator><creator>Kamulyan, Budi</creator><creator>Triatmadja, Radianta</creator><creator>Setiawan, Teguh</creator><general>Trans Tech Publications Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>7TB</scope><scope>8BQ</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>BENPR</scope><scope>BFMQW</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>D1I</scope><scope>DWQXO</scope><scope>FR3</scope><scope>HCIFZ</scope><scope>JG9</scope><scope>KB.</scope><scope>KR7</scope><scope>L6V</scope><scope>M7S</scope><scope>PDBOC</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope></search><sort><creationdate>20180501</creationdate><title>Campus Drinking Water Supply System Performance Analysis Universitas Gadjah Mada of Yogyakarta</title><author>Supraba, Intan ; Kamulyan, Budi ; Triatmadja, Radianta ; Setiawan, Teguh</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1914-a2d50352b65b9bf9e85ff0ae5bbc6c3cd7bc58ce9427611d54c790588892dca03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Construction costs</topic><topic>Current distribution</topic><topic>Dispensers</topic><topic>Distribution management</topic><topic>Drinking water</topic><topic>Measuring instruments</topic><topic>Optimization</topic><topic>Pipes</topic><topic>Water consumption</topic><topic>Water discharge</topic><topic>Water shortages</topic><topic>Water supply</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Supraba, Intan</creatorcontrib><creatorcontrib>Kamulyan, Budi</creatorcontrib><creatorcontrib>Triatmadja, Radianta</creatorcontrib><creatorcontrib>Setiawan, Teguh</creatorcontrib><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science &amp; Engineering Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central</collection><collection>Continental Europe Database</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Materials Science Collection</collection><collection>ProQuest Central Korea</collection><collection>Engineering Research Database</collection><collection>SciTech Premium Collection</collection><collection>Materials Research Database</collection><collection>Materials Science Database</collection><collection>Civil Engineering Abstracts</collection><collection>ProQuest Engineering Collection</collection><collection>Engineering Database</collection><collection>Materials Science Collection</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering Collection</collection><jtitle>Applied Mechanics and Materials</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Supraba, Intan</au><au>Kamulyan, Budi</au><au>Triatmadja, Radianta</au><au>Setiawan, Teguh</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Campus Drinking Water Supply System Performance Analysis Universitas Gadjah Mada of Yogyakarta</atitle><jtitle>Applied Mechanics and Materials</jtitle><date>2018-05-01</date><risdate>2018</risdate><volume>881</volume><spage>64</spage><epage>69</epage><pages>64-69</pages><issn>1660-9336</issn><issn>1662-7482</issn><eissn>1662-7482</eissn><isbn>9783035712698</isbn><isbn>3035712697</isbn><abstract>The decent quality, quantity, and continuity of Drinking Water Supply System (DWSS) are needed to support the activities of a campus. Universitas Gadjah Mada drinking water supply system (UGM-DWSS) provides 49 Water Fountains (WF) and 12 Water Dispensers (WD) to support daily activities for all the campus community. This research aimed at figuring out the performance of the existing UGM-DWSS against the current service pipeline distribution network so that the technical condition of the pipes’ pressure, the water consumption’s discharge, and the pumps’ use can be identified. The method used for analyzing is by implementing simulating the network performance using WaterNet program version 2.2 by which pipes network and its facilities performance including optimization of pipe diameter can be described. The simulation indicated that there was 80% idle capacity of the available water capacity. It is uneconomical to make any changes to the existing pipes’ condition considering the very high cost of the pipeline construction. Therefore, pump replacement was considered more feasible optimization approach. To obtain the optimal results, the pump should be replaced with 4 m3/hours capacity with 20 meters pump design head.</abstract><cop>Zurich</cop><pub>Trans Tech Publications Ltd</pub><doi>10.4028/www.scientific.net/AMM.881.64</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1660-9336
ispartof Applied Mechanics and Materials, 2018-05, Vol.881, p.64-69
issn 1660-9336
1662-7482
1662-7482
language eng
recordid cdi_proquest_journals_2199197995
source Scientific.net Journals
subjects Construction costs
Current distribution
Dispensers
Distribution management
Drinking water
Measuring instruments
Optimization
Pipes
Water consumption
Water discharge
Water shortages
Water supply
title Campus Drinking Water Supply System Performance Analysis Universitas Gadjah Mada of Yogyakarta
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-17T03%3A03%3A16IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Campus%20Drinking%20Water%20Supply%20System%20Performance%20Analysis%20Universitas%20Gadjah%20Mada%20of%20Yogyakarta&rft.jtitle=Applied%20Mechanics%20and%20Materials&rft.au=Supraba,%20Intan&rft.date=2018-05-01&rft.volume=881&rft.spage=64&rft.epage=69&rft.pages=64-69&rft.issn=1660-9336&rft.eissn=1662-7482&rft.isbn=9783035712698&rft.isbn_list=3035712697&rft_id=info:doi/10.4028/www.scientific.net/AMM.881.64&rft_dat=%3Cproquest_cross%3E2199197995%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2199197995&rft_id=info:pmid/&rfr_iscdi=true