5PSQ-010 Manipulation of warfarin tablets in paediatric care: do we give the right dose?

BackgroundManipulation of drug formulations to achieve an appropriate dose is often necessary in the paediatric ward (e.g crushing and dispersion of tablets, followed by extraction of a fraction). However, such manipulation has previously been shown to result in inaccurate dosing for some tablet for...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:European journal of hospital pharmacy. Science and practice 2019-03, Vol.26 (Suppl 1), p.A206-A206
Hauptverfasser: Brustugun, J, Birkedal AAS, E, Tho, I, Bjerknes, K
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:BackgroundManipulation of drug formulations to achieve an appropriate dose is often necessary in the paediatric ward (e.g crushing and dispersion of tablets, followed by extraction of a fraction). However, such manipulation has previously been shown to result in inaccurate dosing for some tablet formulations of the poorly soluble anticoagulant aspirin. Using the same manipulation procedure, a dispersible tablet formulation of aspirin yielded 99% of the intended dose while a chewable tablet yielded only 9%.1 Warfarin is another anticoagulant used in paediatric care. Despite having good solubility, ensuring a reliable dose of this substance is important, considering the narrow therapeutic index of the drug.PurposeTo investigate the dose accuracy and dose precision attained after manipulation of two different warfarin tablets, using validated ultra high-performance liquid chromatography (UHPLC-analysis).Material and methodsWarfarin tablets: Marevan (2.5 mg; Takeda AS, Norway) and Warfarin Orion (2.5 mg; Orion Pharma, Finland). Instrument: UHPLC-system from Shimadzu Corp (Nexera, with Prominence DAD-detector). Analytical column: Inertsil 2 µm C8–3, 2.1 × 100 mm, (GL Sciences Inc., Tokyo, Japan). The analytical method was validated for linearity, precision and specificity. Dosing accuracy study: six tablets from each of the two formulations were individually dissolved in 10 ml water. After 8 min, a sample (1 ml) was withdrawn. Dosing accuracy and precision was recorded and compared between formulations.ResultsFor Warfarin Orion (2.5 mg) 96.5% (SD 4.8; range 89.8%–101.4%) of the intended dose was found. For Marevan (2.5 mg) 101.4% (SD 4.2; range 96.3%–107.2%) of the intended dose was found.ConclusionUsing a validated UHPLC-method, the dosing accuracy upon dispersion and dose extraction from two warfarin tablets (Marevan and Warfarin Orion) was found to be both accurate and precise – unlike that which had previously been published for different aspirin tablets. These results underline the importance of considering both formulation and drug characteristics when manipulating tablets.References and/or acknowledgements1. Notaker N, Brustugun J, Tho I, Bjerknes K. Manipulation and formulation – the tale of two aspirin tablets. Poster abstract. EAHP 2016.No conflict of interest.
ISSN:2047-9956
2047-9964
DOI:10.1136/ejhpharm-2019-eahpconf.443