Directly Heated High Surface Area Solid Phase Microextraction Sampler for Rapid Field Forensic Analyses

A high-surface area solid phase microextraction (HSA-SPME) sampler is described for dynamic sampling at high air velocities (up to several hundred centimeters per second). The sampling device consists of a thin wire coated with carboxen/polydimethylsiloxane (carboxen/PDMS) material, wound in the ann...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analytical chemistry (Washington) 2009-11, Vol.81 (21), p.8724-8733
Hauptverfasser: Ramsey, Scott A, Mustacich, Robert V, Smith, Philip A, Hook, Gary L, Eckenrode, Brian A
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A high-surface area solid phase microextraction (HSA-SPME) sampler is described for dynamic sampling at high air velocities (up to several hundred centimeters per second). The sampling device consists of a thin wire coated with carboxen/polydimethylsiloxane (carboxen/PDMS) material, wound in the annular space between two concentric glass tubes, providing a large trapping surface from which analytes may then be thermally desorbed with little power consumption upon resistive heating of the wire. Desorbed analytes are focused and reconcentrated on a microtrap that is subsequently resistively heated to introduce analytes for GC or GC/MS analysis. Benzene, toluene, ethylbenzene, and xylenes (BTEX) included in a 39-component toxic organics (TO-14) gas mixture were used to evaluate the efficiency of the HSA-SPME sampler. Quantitation of trace-level BTEX compounds present during weapons cleaning was completed using stepwise calibration. Detection limits of 0.2−6.9 pptrv were observed for these analytes using single ion monitoring GC/MS analysis, and an improvement in sensitivity of several orders of magnitude was achieved when compared to standard dynamic flow SPME with a commercially available 10 mm carboxen/PDMS fiber. The potential for rapid analyte uptake and improved sensitivity using the HSA-SPME design will make it possible to rapidly collect and analyze VOC samples in field settings using a portable hand-held pump and a small, low power GC/MS instrument. This system will be especially useful for situations involving forensics, public safety, and military defensive or intelligence needs where rapid, sensitive detection of airborne analytes is required.
ISSN:0003-2700
1520-6882
DOI:10.1021/ac900565s