QCM response to solvated, tethered marcomolecules

When the quartz crystal microbalance (QCM) is operated in contact with solution and used to detect inertia increases caused by macromolecules binding to its surface, resonance frequency shifts are reported in the literature to be greater than, less than, and the same as an identical macromolecular m...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analytical chemistry (Washington) 1998-07, Vol.70 (14), p.2876
Hauptverfasser: Fawcett, Newton C, Craven, Richard D, Zhang, Ping, Evans, Jeffrey A
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 14
container_start_page 2876
container_title Analytical chemistry (Washington)
container_volume 70
creator Fawcett, Newton C
Craven, Richard D
Zhang, Ping
Evans, Jeffrey A
description When the quartz crystal microbalance (QCM) is operated in contact with solution and used to detect inertia increases caused by macromolecules binding to its surface, resonance frequency shifts are reported in the literature to be greater than, less than, and the same as an identical macromolecular mass would cause as a dry layer. A previous report of wet and dry M13 DNA giving the same, linear frequency versus mass response is examined.
format Article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_journals_217871483</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>32595517</sourcerecordid><originalsourceid>FETCH-proquest_journals_2178714833</originalsourceid><addsrcrecordid>eNqNyr8KwjAQgPEgCtY_7xCcLdyl2mQviouD4F5KeyIl7dVc4vPr4AM4fcPvm6kMjwby0jkzVxkAFLmxAEu1EukBEAHLTOGtuupAMvEopCNrYf9uInV7HSk-KVCnhya0PLCnNnmSjVo8Gi-0_XWtdufTvbrkU-BXIol1zymMX6oNWmfx4Irir-kDDWU0XA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>217871483</pqid></control><display><type>article</type><title>QCM response to solvated, tethered marcomolecules</title><source>ACS Publications</source><creator>Fawcett, Newton C ; Craven, Richard D ; Zhang, Ping ; Evans, Jeffrey A</creator><creatorcontrib>Fawcett, Newton C ; Craven, Richard D ; Zhang, Ping ; Evans, Jeffrey A</creatorcontrib><description>When the quartz crystal microbalance (QCM) is operated in contact with solution and used to detect inertia increases caused by macromolecules binding to its surface, resonance frequency shifts are reported in the literature to be greater than, less than, and the same as an identical macromolecular mass would cause as a dry layer. A previous report of wet and dry M13 DNA giving the same, linear frequency versus mass response is examined.</description><identifier>ISSN: 0003-2700</identifier><identifier>EISSN: 1520-6882</identifier><identifier>CODEN: ANCHAM</identifier><language>eng</language><publisher>Washington: American Chemical Society</publisher><subject>Chemistry ; Molecules</subject><ispartof>Analytical chemistry (Washington), 1998-07, Vol.70 (14), p.2876</ispartof><rights>Copyright American Chemical Society Jul 15, 1998</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,778,782</link.rule.ids></links><search><creatorcontrib>Fawcett, Newton C</creatorcontrib><creatorcontrib>Craven, Richard D</creatorcontrib><creatorcontrib>Zhang, Ping</creatorcontrib><creatorcontrib>Evans, Jeffrey A</creatorcontrib><title>QCM response to solvated, tethered marcomolecules</title><title>Analytical chemistry (Washington)</title><description>When the quartz crystal microbalance (QCM) is operated in contact with solution and used to detect inertia increases caused by macromolecules binding to its surface, resonance frequency shifts are reported in the literature to be greater than, less than, and the same as an identical macromolecular mass would cause as a dry layer. A previous report of wet and dry M13 DNA giving the same, linear frequency versus mass response is examined.</description><subject>Chemistry</subject><subject>Molecules</subject><issn>0003-2700</issn><issn>1520-6882</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1998</creationdate><recordtype>article</recordtype><recordid>eNqNyr8KwjAQgPEgCtY_7xCcLdyl2mQviouD4F5KeyIl7dVc4vPr4AM4fcPvm6kMjwby0jkzVxkAFLmxAEu1EukBEAHLTOGtuupAMvEopCNrYf9uInV7HSk-KVCnhya0PLCnNnmSjVo8Gi-0_XWtdufTvbrkU-BXIol1zymMX6oNWmfx4Irir-kDDWU0XA</recordid><startdate>19980715</startdate><enddate>19980715</enddate><creator>Fawcett, Newton C</creator><creator>Craven, Richard D</creator><creator>Zhang, Ping</creator><creator>Evans, Jeffrey A</creator><general>American Chemical Society</general><scope>7QF</scope><scope>7QO</scope><scope>7QQ</scope><scope>7SC</scope><scope>7SE</scope><scope>7SP</scope><scope>7SR</scope><scope>7TA</scope><scope>7TB</scope><scope>7TM</scope><scope>7U5</scope><scope>7U7</scope><scope>7U9</scope><scope>8BQ</scope><scope>8FD</scope><scope>C1K</scope><scope>F28</scope><scope>FR3</scope><scope>H8D</scope><scope>H8G</scope><scope>H94</scope><scope>JG9</scope><scope>JQ2</scope><scope>KR7</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>P64</scope></search><sort><creationdate>19980715</creationdate><title>QCM response to solvated, tethered marcomolecules</title><author>Fawcett, Newton C ; Craven, Richard D ; Zhang, Ping ; Evans, Jeffrey A</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_journals_2178714833</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1998</creationdate><topic>Chemistry</topic><topic>Molecules</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Fawcett, Newton C</creatorcontrib><creatorcontrib>Craven, Richard D</creatorcontrib><creatorcontrib>Zhang, Ping</creatorcontrib><creatorcontrib>Evans, Jeffrey A</creatorcontrib><collection>Aluminium Industry Abstracts</collection><collection>Biotechnology Research Abstracts</collection><collection>Ceramic Abstracts</collection><collection>Computer and Information Systems Abstracts</collection><collection>Corrosion Abstracts</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Materials Business File</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Nucleic Acids Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Toxicology Abstracts</collection><collection>Virology and AIDS Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Copper Technical Reference Library</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts – Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>Biotechnology and BioEngineering Abstracts</collection><jtitle>Analytical chemistry (Washington)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Fawcett, Newton C</au><au>Craven, Richard D</au><au>Zhang, Ping</au><au>Evans, Jeffrey A</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>QCM response to solvated, tethered marcomolecules</atitle><jtitle>Analytical chemistry (Washington)</jtitle><date>1998-07-15</date><risdate>1998</risdate><volume>70</volume><issue>14</issue><spage>2876</spage><pages>2876-</pages><issn>0003-2700</issn><eissn>1520-6882</eissn><coden>ANCHAM</coden><abstract>When the quartz crystal microbalance (QCM) is operated in contact with solution and used to detect inertia increases caused by macromolecules binding to its surface, resonance frequency shifts are reported in the literature to be greater than, less than, and the same as an identical macromolecular mass would cause as a dry layer. A previous report of wet and dry M13 DNA giving the same, linear frequency versus mass response is examined.</abstract><cop>Washington</cop><pub>American Chemical Society</pub></addata></record>
fulltext fulltext
identifier ISSN: 0003-2700
ispartof Analytical chemistry (Washington), 1998-07, Vol.70 (14), p.2876
issn 0003-2700
1520-6882
language eng
recordid cdi_proquest_journals_217871483
source ACS Publications
subjects Chemistry
Molecules
title QCM response to solvated, tethered marcomolecules
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-16T20%3A12%3A19IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=QCM%20response%20to%20solvated,%20tethered%20marcomolecules&rft.jtitle=Analytical%20chemistry%20(Washington)&rft.au=Fawcett,%20Newton%20C&rft.date=1998-07-15&rft.volume=70&rft.issue=14&rft.spage=2876&rft.pages=2876-&rft.issn=0003-2700&rft.eissn=1520-6882&rft.coden=ANCHAM&rft_id=info:doi/&rft_dat=%3Cproquest%3E32595517%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=217871483&rft_id=info:pmid/&rfr_iscdi=true