Optimization of the Parameters in Supercritical Fluid Extraction of Polynuclear Aromatic Hydrocarbons from Soil Samples
A study examined the effects of extraction pressure, temperature, fluid volume, cosolvents, flow rate, restrictor temperature and sample collection method on supercritical fluid extraction recovery of a series of polynuclear aromatic hydrocarbons in soil samples.
Gespeichert in:
Veröffentlicht in: | Analytical chemistry (Washington) 1994-06, Vol.66 (11), p.1808-1816 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A study examined the effects of extraction pressure, temperature, fluid volume, cosolvents, flow rate, restrictor temperature and sample collection method on supercritical fluid extraction recovery of a series of polynuclear aromatic hydrocarbons in soil samples. |
---|---|
ISSN: | 0003-2700 1520-6882 |
DOI: | 10.1021/ac00083a006 |