Detection of Cross-Turn-On and Selection of Off Drive Voltage for an SiC Power Module

Cross-turn-on happens in a phase leg comprising high-side switch(es) and low-side switch(es) when the turn-on of one switch inadvertently triggers the channel current to flow in the off-switch. The terminal current does not reflect the internal channel current because of the numerous parasitic induc...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on industrial electronics (1982) 2017-11, Vol.64 (11), p.9064-9071
Hauptverfasser: Zichen Miao, Yincan Mao, Chi-Ming Wang, Ngo, Khai D. T.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Cross-turn-on happens in a phase leg comprising high-side switch(es) and low-side switch(es) when the turn-on of one switch inadvertently triggers the channel current to flow in the off-switch. The terminal current does not reflect the internal channel current because of the numerous parasitic inductances from the package. Detection of the cross-turn-on in a power module is difficult since the dice are usually encapsulated and the channel currents are hard to measure. A nonintrusive method to identify the cross-turn-on based on the changing ringing current is introduced in this paper. The detection method is analyzed theoretically and validated by experiments using a 1.2-kV SiC module. The negative drive voltage and gate resistance for safe operation can be determined by the detection method.
ISSN:0278-0046
1557-9948
DOI:10.1109/TIE.2017.2716872