Detection of Cross-Turn-On and Selection of Off Drive Voltage for an SiC Power Module
Cross-turn-on happens in a phase leg comprising high-side switch(es) and low-side switch(es) when the turn-on of one switch inadvertently triggers the channel current to flow in the off-switch. The terminal current does not reflect the internal channel current because of the numerous parasitic induc...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on industrial electronics (1982) 2017-11, Vol.64 (11), p.9064-9071 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Cross-turn-on happens in a phase leg comprising high-side switch(es) and low-side switch(es) when the turn-on of one switch inadvertently triggers the channel current to flow in the off-switch. The terminal current does not reflect the internal channel current because of the numerous parasitic inductances from the package. Detection of the cross-turn-on in a power module is difficult since the dice are usually encapsulated and the channel currents are hard to measure. A nonintrusive method to identify the cross-turn-on based on the changing ringing current is introduced in this paper. The detection method is analyzed theoretically and validated by experiments using a 1.2-kV SiC module. The negative drive voltage and gate resistance for safe operation can be determined by the detection method. |
---|---|
ISSN: | 0278-0046 1557-9948 |
DOI: | 10.1109/TIE.2017.2716872 |