Numerical simulation of vertical flow wetlands with special emphasis on treatment performance during winter

In Austria, single-stage vertical flow (VF) wetlands with intermittent loading are a state-of-the-art technology for treating domestic wastewater. They are designed according to the Austrian design standard with a specific surface area of 4 m per person (i.e. 20 g COD/(m ·d)) and thus demand a bigge...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Water science and technology 2018-12, Vol.78 (9), p.2019-2026
Hauptverfasser: Martí, Alba Canet, Pucher, Bernhard, Hernández-Crespo, Carmen, Monerris, Miguel Martín, Langergraber, Guenter
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In Austria, single-stage vertical flow (VF) wetlands with intermittent loading are a state-of-the-art technology for treating domestic wastewater. They are designed according to the Austrian design standard with a specific surface area of 4 m per person (i.e. 20 g COD/(m ·d)) and thus demand a bigger amount of land to treat the same amount of wastewater compared to intensified technical treatment systems. In order to reduce the amount of land needed, a modified design for VF wetlands has been proposed. The modified design has a specific surface area of 2.5 m per person (i.e. 32 g COD/(m ·d)) and it has been shown to be able to meet the Austrian effluent requirements. To allow higher organic loading, more loadings per day but lower volume of a single loading, a constant loading interval, and increased number of openings per m are applied. A simulation study using the HYDRUS Wetland Module was carried out to compare the treatment efficiencies of single-stage VF wetlands with classical and modified design. Data from a classical Austrian single-stage VF wetland was used for calibration of the model using the standard parameter set for the CW2D biokinetic model. The influent COD fractionation was calibrated to adapt to the wastewater. The simulations showed a good performance of the modified design compared to a classical VF wetland for COD removal with COD effluent concentrations in winter (effluent water temperature of 4.5 °C) of 35 and 29 mg/L, respectively. The simulation study showed that during high-loading events the VF wetland with modified design has lower maximum NH -N effluent concentrations. Single-stage VF wetlands with modified design seem to be very effective and allow application of higher organic loads compared to single-stage VF wetlands with classical design.
ISSN:0273-1223
1996-9732
DOI:10.2166/wst.2018.479