Determination of the Life Cycle of Heat-Exchange Tubes of Vapor Condensers on the Basis of Statistical Analysis of Local Pitting Corrosion According to Data of Eddy Current Testing

The possibility is shown of creating a chart of local corrosion damage in the walls of heat-exchange tubes on the basis of the data of matrix eddy current testing with registration of the position, type, and depth of all local corrosion damage areas. The results of examination of condensers operated...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Protection of metals and physical chemistry of surfaces 2018-11, Vol.54 (6), p.1221-1232
Hauptverfasser: Golovin, V. A., Pechnikov, N. V., Shchelkov, V. A., Tsivadze, A. Yu
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The possibility is shown of creating a chart of local corrosion damage in the walls of heat-exchange tubes on the basis of the data of matrix eddy current testing with registration of the position, type, and depth of all local corrosion damage areas. The results of examination of condensers operated under different conditions and at different plants are used to calculate the theoretical depth distribution of defects. It is shown that, in all cases, a satisfactory statistical description of the corrosion defect depth on the cooling water size is obtained by employing the Weibull distribution. Pearson’s coefficient is in the range of 0.994–0.997.
ISSN:2070-2051
2070-206X
DOI:10.1134/S2070205118060138