Comparison of QTinno, a fully automated electrocardiographic analysis program, to semiautomated electrocardiographic analysis methods in a drug safety study in healthy subjects
Abstract Background Improved automated methods for electrocardiographic (ECG) analysis are needed, particularly for drug development purposes. Objectives This study compared a novel fully automated method for ECG analysis (QTinno; NewCardio, Santa Clara, CA) to 2 semiautomated digital methods: globa...
Gespeichert in:
Veröffentlicht in: | Journal of electrocardiology 2009-07, Vol.42 (4), p.358-366 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Abstract Background Improved automated methods for electrocardiographic (ECG) analysis are needed, particularly for drug development purposes. Objectives This study compared a novel fully automated method for ECG analysis (QTinno; NewCardio, Santa Clara, CA) to 2 semiautomated digital methods: global measurement from the earliest QRS onset to the latest T-wave offset on representative superimposed beats (global) and tangent measurement on 3 consecutive beats in one lead (tangent). Methods All 3 methods were used to determine uncorrected and rate-corrected QT interval duration (QT and QTcF) and related metrics in 1422 digital 12-lead ECGs from a phase 1 drug study. Global and tangent annotations were manually adjusted by the same 3 cardiologists wherever necessary. No adjustments were made in QTinno determinations. Results QTinno returned QTcF change from time-matched baseline (ΔQTcF) that differed minimally from both global and tangent methods (mean pairwise difference: 0.1 millisecond between QTinno and global, 1.1 milliseconds between QTinno and tangent). The average absolute QT and QTcF intervals by QTinno were approximately 5 milliseconds longer than global and 25 milliseconds longer than by tangent. QTinno had lower intrinsic variability for ΔQTcF than either global or tangent (between-subject SD: QTinno 4.0 milliseconds, global 5.6 milliseconds, tangent 6.4 milliseconds; within-subject SD: QTinno 4.8 milliseconds, global 7.4 milliseconds, tangent 10.6 milliseconds). All methods were robust in detecting the largest placebo-adjusted mean time-matched ΔQTcF (15-25 milliseconds) induced by study drug. Conclusions The methods show good agreement for drug-induced QTc prolongation. Lower intrinsic variability of ΔQTcF by QTinno could facilitate smaller sample sizes or increase study power in thorough QTc studies. |
---|---|
ISSN: | 0022-0736 1532-8430 |
DOI: | 10.1016/j.jelectrocard.2009.02.001 |