RAPID REMOVAL OF PARACETAMOL BY HÆMOPERFUSION THROUGH COATED CHARCOAL In-vivo and In-vitro Studies in the Pig

Using a method based on hæmoperfusion through a column of polyhydroxyethylmethacrylate (polyhema)-coated charcoal, paracetamol is rapidly removed from the pig, without loss of leucocytes or platelets, or particle embolism. These findings, together with rapid and simple assembly of the perfusion circ...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Lancet (British edition) 1973-01, Vol.301 (7794), p.77-79
Hauptverfasser: Willson, R.A., Thompson, R.P.H., Winch, J., Williams, Roger
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Using a method based on hæmoperfusion through a column of polyhydroxyethylmethacrylate (polyhema)-coated charcoal, paracetamol is rapidly removed from the pig, without loss of leucocytes or platelets, or particle embolism. These findings, together with rapid and simple assembly of the perfusion circuit, provide all the theoretical requirements for the successful use of this method in man.