Comments on “Pressure drop of HFE7000 and HFE7100 during flow condensation in minichannels”
•These comments are increasing the awareness among the journal readers.•Comments are presented in particular on the paper by Mikielewicz et al. (2016).•Comments are presented on the separated flow model.•Comments are presented on the Blasius friction correlation. These comments are presented to incr...
Gespeichert in:
Veröffentlicht in: | International journal of refrigeration 2018-11, Vol.95, p.189-190 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 190 |
---|---|
container_issue | |
container_start_page | 189 |
container_title | International journal of refrigeration |
container_volume | 95 |
creator | Awad, M.M. |
description | •These comments are increasing the awareness among the journal readers.•Comments are presented in particular on the paper by Mikielewicz et al. (2016).•Comments are presented on the separated flow model.•Comments are presented on the Blasius friction correlation.
These comments are presented to increase the awareness among the readers of International Journal of Refrigeration. Comments are presented in particular on the paper by Mikielewicz et al. (2016) where the authors presented some incorrect information and equations in their analysis about the separated flow model. We use the separated flow model to develop frictional pressure drop models. Also, some lights on the Blasius's (1913) friction correlation are presented. |
doi_str_mv | 10.1016/j.ijrefrig.2018.05.040 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2153614695</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0140700718302032</els_id><sourcerecordid>2153614695</sourcerecordid><originalsourceid>FETCH-LOGICAL-c287t-f2505ed2c58e0e452b5cec7ea6dba1fe958dc6a060c0c87359f02f0759455cba3</originalsourceid><addsrcrecordid>eNqFkEtOwzAQhi0EEqVwBWSJdcI4jfPYgaqWIlWCBawt154UR41d7BTErgeBy_UkuBTWrOZf_A_NR8glg5QBK67b1LQeG2-WaQasSoGnkMMRGbCqrJMMKnZMBsBySEqA8pSchdACsBJ4NSBi7LoObR-os3S3_Xz0GMLGI9Xeralr6Gw6iTGg0uofzaLWG2_skjYr906VsxptkL2JBcbSzlijXqS1uAq77dc5OWnkKuDF7x2S5-nkaTxL5g939-PbeaKyquyTJuPAUWeKVwiY82zBFaoSZaEXkjVY80qrQkIBClRVjnjdQNZAyeucc7WQoyG5OvSuvXvdYOhF6zbexkmRMT4qWF7UPLqKg0t5F0KEJtbedNJ_CAZiD1O04g-m2MMUwEWEGYM3h2D8Ct8MehGUQatQG4-qF9qZ_yq-AbH5gcQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2153614695</pqid></control><display><type>article</type><title>Comments on “Pressure drop of HFE7000 and HFE7100 during flow condensation in minichannels”</title><source>Elsevier ScienceDirect Journals Complete</source><creator>Awad, M.M.</creator><creatorcontrib>Awad, M.M.</creatorcontrib><description>•These comments are increasing the awareness among the journal readers.•Comments are presented in particular on the paper by Mikielewicz et al. (2016).•Comments are presented on the separated flow model.•Comments are presented on the Blasius friction correlation.
These comments are presented to increase the awareness among the readers of International Journal of Refrigeration. Comments are presented in particular on the paper by Mikielewicz et al. (2016) where the authors presented some incorrect information and equations in their analysis about the separated flow model. We use the separated flow model to develop frictional pressure drop models. Also, some lights on the Blasius's (1913) friction correlation are presented.</description><identifier>ISSN: 0140-7007</identifier><identifier>EISSN: 1879-2081</identifier><identifier>DOI: 10.1016/j.ijrefrig.2018.05.040</identifier><language>eng</language><publisher>Paris: Elsevier Ltd</publisher><subject>Condensation ; Flow velocity ; Heat ; Heat flux ; Pressure drop ; Pressure measurement ; Temperature effects</subject><ispartof>International journal of refrigeration, 2018-11, Vol.95, p.189-190</ispartof><rights>2018</rights><rights>Copyright Elsevier Science Ltd. Nov 2018</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c287t-f2505ed2c58e0e452b5cec7ea6dba1fe958dc6a060c0c87359f02f0759455cba3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.ijrefrig.2018.05.040$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids></links><search><creatorcontrib>Awad, M.M.</creatorcontrib><title>Comments on “Pressure drop of HFE7000 and HFE7100 during flow condensation in minichannels”</title><title>International journal of refrigeration</title><description>•These comments are increasing the awareness among the journal readers.•Comments are presented in particular on the paper by Mikielewicz et al. (2016).•Comments are presented on the separated flow model.•Comments are presented on the Blasius friction correlation.
These comments are presented to increase the awareness among the readers of International Journal of Refrigeration. Comments are presented in particular on the paper by Mikielewicz et al. (2016) where the authors presented some incorrect information and equations in their analysis about the separated flow model. We use the separated flow model to develop frictional pressure drop models. Also, some lights on the Blasius's (1913) friction correlation are presented.</description><subject>Condensation</subject><subject>Flow velocity</subject><subject>Heat</subject><subject>Heat flux</subject><subject>Pressure drop</subject><subject>Pressure measurement</subject><subject>Temperature effects</subject><issn>0140-7007</issn><issn>1879-2081</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNqFkEtOwzAQhi0EEqVwBWSJdcI4jfPYgaqWIlWCBawt154UR41d7BTErgeBy_UkuBTWrOZf_A_NR8glg5QBK67b1LQeG2-WaQasSoGnkMMRGbCqrJMMKnZMBsBySEqA8pSchdACsBJ4NSBi7LoObR-os3S3_Xz0GMLGI9Xeralr6Gw6iTGg0uofzaLWG2_skjYr906VsxptkL2JBcbSzlijXqS1uAq77dc5OWnkKuDF7x2S5-nkaTxL5g939-PbeaKyquyTJuPAUWeKVwiY82zBFaoSZaEXkjVY80qrQkIBClRVjnjdQNZAyeucc7WQoyG5OvSuvXvdYOhF6zbexkmRMT4qWF7UPLqKg0t5F0KEJtbedNJ_CAZiD1O04g-m2MMUwEWEGYM3h2D8Ct8MehGUQatQG4-qF9qZ_yq-AbH5gcQ</recordid><startdate>201811</startdate><enddate>201811</enddate><creator>Awad, M.M.</creator><general>Elsevier Ltd</general><general>Elsevier Science Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7TB</scope><scope>8FD</scope><scope>FR3</scope></search><sort><creationdate>201811</creationdate><title>Comments on “Pressure drop of HFE7000 and HFE7100 during flow condensation in minichannels”</title><author>Awad, M.M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c287t-f2505ed2c58e0e452b5cec7ea6dba1fe958dc6a060c0c87359f02f0759455cba3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Condensation</topic><topic>Flow velocity</topic><topic>Heat</topic><topic>Heat flux</topic><topic>Pressure drop</topic><topic>Pressure measurement</topic><topic>Temperature effects</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Awad, M.M.</creatorcontrib><collection>CrossRef</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><jtitle>International journal of refrigeration</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Awad, M.M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comments on “Pressure drop of HFE7000 and HFE7100 during flow condensation in minichannels”</atitle><jtitle>International journal of refrigeration</jtitle><date>2018-11</date><risdate>2018</risdate><volume>95</volume><spage>189</spage><epage>190</epage><pages>189-190</pages><issn>0140-7007</issn><eissn>1879-2081</eissn><abstract>•These comments are increasing the awareness among the journal readers.•Comments are presented in particular on the paper by Mikielewicz et al. (2016).•Comments are presented on the separated flow model.•Comments are presented on the Blasius friction correlation.
These comments are presented to increase the awareness among the readers of International Journal of Refrigeration. Comments are presented in particular on the paper by Mikielewicz et al. (2016) where the authors presented some incorrect information and equations in their analysis about the separated flow model. We use the separated flow model to develop frictional pressure drop models. Also, some lights on the Blasius's (1913) friction correlation are presented.</abstract><cop>Paris</cop><pub>Elsevier Ltd</pub><doi>10.1016/j.ijrefrig.2018.05.040</doi><tpages>2</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0140-7007 |
ispartof | International journal of refrigeration, 2018-11, Vol.95, p.189-190 |
issn | 0140-7007 1879-2081 |
language | eng |
recordid | cdi_proquest_journals_2153614695 |
source | Elsevier ScienceDirect Journals Complete |
subjects | Condensation Flow velocity Heat Heat flux Pressure drop Pressure measurement Temperature effects |
title | Comments on “Pressure drop of HFE7000 and HFE7100 during flow condensation in minichannels” |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T10%3A03%3A52IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comments%20on%20%E2%80%9CPressure%20drop%20of%20HFE7000%20and%20HFE7100%20during%20flow%20condensation%20in%20minichannels%E2%80%9D&rft.jtitle=International%20journal%20of%20refrigeration&rft.au=Awad,%20M.M.&rft.date=2018-11&rft.volume=95&rft.spage=189&rft.epage=190&rft.pages=189-190&rft.issn=0140-7007&rft.eissn=1879-2081&rft_id=info:doi/10.1016/j.ijrefrig.2018.05.040&rft_dat=%3Cproquest_cross%3E2153614695%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2153614695&rft_id=info:pmid/&rft_els_id=S0140700718302032&rfr_iscdi=true |