PO-0540 Changes In Haemodynamic And Peripheral Perfusion In Suspected Neonatal Sepsis
BackgroundImpaired hemodynamics in neonatal sepsis increase the mortality.ObjectiveStudying the changes in hemodynamics and peripheral perfusion in premature infants with suspected sepsis and comparing them with stable matched controls.MethodsLeft (LVO) and right ventricular output (RVO), and superi...
Gespeichert in:
Veröffentlicht in: | Archives of disease in childhood 2014-10, Vol.99 (Suppl 2), p.A426-A426 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | BackgroundImpaired hemodynamics in neonatal sepsis increase the mortality.ObjectiveStudying the changes in hemodynamics and peripheral perfusion in premature infants with suspected sepsis and comparing them with stable matched controls.MethodsLeft (LVO) and right ventricular output (RVO), and superior vena cava (SVC) flow were measured using echocardiography in newborn infants with suspected sepsis after DOL 7. Measurements were repeated 3 times q 24 h and when antibiotics were discontinued. Anterior cerebral artery RI and oxygenation of the brain and the kidney were measured by near infrared spectroscopy (NIRS). Vital parameters were monitored. Controls were studied once; matched with cases for GA, BW, and postnatal age.ResultsTwelve preterm infants (GA 26.8 ± 2.5 wks; BW 843 ± 225 g) were studied at postnatal age 13.5 (7- 60) days and compared to 12 stable matched controls. Four cases had a positive blood culture, six had an elevated CrP, and 2 had an elevated IL8 only. LVO showed an increase over time reaching a maximum of 404 ± 104 ml/kg/min on the 3rd measurement point (p = 0.046 compared to the 1st measurement) and was higher compared to controls (p = 0.04). SVC flow showed a trend towards increase over time. The control group had a higher SVC flow at the initial measurement (p = 0.05). No significant change in RVO, NIRS, Doppler parameters, and in blood pressure over time or compared to controls, although five cases required circulatory support either by volume therapy, catecholamines or both.ConclusionsSuspected sepsis was associated with haemodynamic changes which may have implications for clinical management.Abstract PO-0540 Figure 1Average ±SD of left ventricular output (LVO) changes over time, after clinical improvement and LVO in the control group. D/C Abx, discontinuation of antibiotics.[Figure omitted. See PDF] |
---|---|
ISSN: | 0003-9888 1468-2044 |
DOI: | 10.1136/archdischild-2014-307384.1184 |