Layerwise monitoring of electron beam melting via backscatter electron detection

Purpose The purpose of this study is the introduction and validation of a new technique for process monitoring during electron beam melting (EBM). Design/methodology/approach In this study, a backscatter electron detector inside the building chamber is used for image acquisition during EBM process....

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Rapid prototyping journal 2018-11, Vol.24 (8), p.1401-1406
Hauptverfasser: Arnold, Christopher, Pobel, Christoph, Osmanlic, Fuad, Körner, Carolin
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Purpose The purpose of this study is the introduction and validation of a new technique for process monitoring during electron beam melting (EBM). Design/methodology/approach In this study, a backscatter electron detector inside the building chamber is used for image acquisition during EBM process. By systematic variation of process parameters, the ability of displaying different topographies, especially pores, is investigated. The results are evaluated in terms of porosity and compared with optical microscopy and X-ray computed tomography. Findings The method is capable of detecting major flaws (e.g. pores) and gives information about the quality of the resulting component. Originality/value Image acquisition by evaluating backscatter electrons during EBM process is a new approach in process monitoring which avoids disadvantages restricting previously investigated techniques.
ISSN:1355-2546
1758-7670
DOI:10.1108/RPJ-02-2018-0034