Failure mechanism of Ag-4Pd alloy wire bonded on Al-Si metallization under high temperature storage and thermal cycle tests in corrosive environments

This study investigated the failure mechanism of Ag-4Pd wire bonded on Al metallization under chlorine corrosive environments after high temperature storage tests (HTST) and thermal cycle tests (TCT). Results show that as-bonded samples encountered the fastest failure, caused by corrosion of Al meta...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Materials chemistry and physics 2018-10, Vol.218, p.147-153
Hauptverfasser: Wang, Jui-Nung, Tsau, Yan-Wen, Ouyang, Fan-Yi
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This study investigated the failure mechanism of Ag-4Pd wire bonded on Al metallization under chlorine corrosive environments after high temperature storage tests (HTST) and thermal cycle tests (TCT). Results show that as-bonded samples encountered the fastest failure, caused by corrosion of Al metallization accelerated by galvanic corrosion. For HTST samples, the intermetallic compound (IMC) layer was corroded and separated into the upper layer of Ag2Al and Ag3Al and the lower layer of Ag3Al2. The non-continuous Ag3Al2 IMC layers in TCT samples can act as a barrier to inhibit the galvanic corrosion and effectively retard the corrosion rate of Al metallization. •Corrosion of Ag-4Pd/Al bonding after high temperature storage and temperature cycle.•As-bonded samples exhibit largest bonding strength than the other two conditions.•Fastest corrosion of Al pads in as-bonded samples due to galvanic corrosion.•Ag2Al and Ag3Al were corroded for samples after high temperature storage test.•Ag3Al2 acts as a barrier to inhibit corrosion for samples after temperature cycles.
ISSN:0254-0584
1879-3312
DOI:10.1016/j.matchemphys.2018.07.021