Maximizing the efficiency of a 4-cell FK module
The outdoor measurements of both a single-cell and a 4-cell CPV modules reaching, respectively, maximum peak efficiencies of 36.0% and 34.8% (both corrected @Tcell=25°C) are presented. This is the result of the joint effort by LPI and Solar Junction to demonstrate the potential of combining their re...
Gespeichert in:
Hauptverfasser: | , , , , , , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The outdoor measurements of both a single-cell and a 4-cell CPV modules reaching, respectively, maximum peak efficiencies of 36.0% and 34.8% (both corrected @Tcell=25°C) are presented. This is the result of the joint effort by LPI and Solar Junction to demonstrate the potential of combining their respective state-of-the-art concentrator optics and solar cells. The LPI concentrator used is a Fresnel Köhler(FK), which is an advanced nonimaging concentrator using 4-channel Köhler homogenization, based on a primary Fresnel lens and a free-form secondary glass lens. Solar Junction's cell is a triple-junction solar cell with the A-SLAM{trade mark, serif} architecture using dilute-nitrides. |
---|---|
ISSN: | 0094-243X 1551-7616 |
DOI: | 10.1063/1.4897058 |