Nano Impact Electrochemistry: Effects of Electronic Filtering on Peak Height, Duration and Area

Nano impact electrochemistry is used to measure a transient signal while a nanoparticle (NP) hits an electrode due to its motion in a solution. A variety of information can be obtained from this current pulse, yet its accurate measurement is challenging due to its short duration (μs to s) and small...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:ChemElectroChem 2018-10, Vol.5 (20), p.3000-3005
Hauptverfasser: Kanokkanchana, Kannasoot, Saw, En N., Tschulik, Kristina
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Nano impact electrochemistry is used to measure a transient signal while a nanoparticle (NP) hits an electrode due to its motion in a solution. A variety of information can be obtained from this current pulse, yet its accurate measurement is challenging due to its short duration (μs to s) and small amplitude (≤10 nA). A typically used low bandwidth low‐pass filter can improve the signal‐to‐noise ratio, but it may cost severely in the accuracy of the data. Here, we demonstrate the effects of electronic filters by using generated current impulses with duration from 125 μs to 8 ms. Initially, a system dedicated to measure short and low current impulses was employed. There, an 8th order Bessel filter was used and the effect of varying the cut‐off frequency between 50 Hz and 20 kHz on the impulse response is studied. Even though the charge is generally conserved by the filter, amplitude and duration of the pulse vary greatly in dependence of the cut‐off frequency. In comparison, the response of widely used potentiostats was tested and significant deviations of the measured signal from the input were detected. Supported by destructive nano impact experiments with Ag NPs in KCl(aq), we show how the filtering affects the experimentally determined size of Ag NPs and Cl− diffusion coefficient, using impact charges and duration, respectively. As a result, we suggest a general guideline to researchers for accurate electrochemical nano impact measurements, in particular with respect to current peak duration analysis. Are nano impact results reliable? An accurate measurement of nano impact signals is crucial to obtain reliable coulometric and mechanistic information from particle collision experiments. It is shown that the signals are often significantly modified by electronic filters in potentiostats. This potentially results in inaccuracy and misinterpretation of the results. Therefore, a simple method for researchers is provided to test and validate their experimental setup.
ISSN:2196-0216
2196-0216
DOI:10.1002/celc.201800738