Estimation of Etoricoxib in Tablet Dosage form by RP- HPLC using Internal Standard with Emphasize on Specificity Parameter Method

A simple, precise and rapid RP-HPLC method was developed for the estimation of etoricoxib in pharmaceutical dosage forms. The method was carried out on a ODS Hypersil C18 (250 x 4.6 mm) column using a mixture of acetonitrile: water (55:45 v/v). The detection was carried out at 269 nm using caffeine...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Oriental journal of chemistry 2011-01, Vol.27 (2), p.697
Hauptverfasser: Bagade, S B, Meshram, D B, Tajne, M R
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A simple, precise and rapid RP-HPLC method was developed for the estimation of etoricoxib in pharmaceutical dosage forms. The method was carried out on a ODS Hypersil C18 (250 x 4.6 mm) column using a mixture of acetonitrile: water (55:45 v/v). The detection was carried out at 269 nm using caffeine as an internal standard. The linearity was found to be 10 to 60μg/ml injection with correlation coefficient of 0.999. The percentage recovery was found to be 99.24± 1.064 to 102.66±1.22. The result of analysis of marketed formulation was found to be 99.09±0.473 to 99.55±0.493%. The method was validated and studied for the various parameters like accuracy, precision, ruggedness and specificity study . The proposed method was successfully applied for the estimation of etoricoxib in pharmaceutical dosage forms.
ISSN:0970-020X
2231-5039