Estimation of Etoricoxib in Tablet Dosage form by RP- HPLC using Internal Standard with Emphasize on Specificity Parameter Method
A simple, precise and rapid RP-HPLC method was developed for the estimation of etoricoxib in pharmaceutical dosage forms. The method was carried out on a ODS Hypersil C18 (250 x 4.6 mm) column using a mixture of acetonitrile: water (55:45 v/v). The detection was carried out at 269 nm using caffeine...
Gespeichert in:
Veröffentlicht in: | Oriental journal of chemistry 2011-01, Vol.27 (2), p.697 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A simple, precise and rapid RP-HPLC method was developed for the estimation of etoricoxib in pharmaceutical dosage forms. The method was carried out on a ODS Hypersil C18 (250 x 4.6 mm) column using a mixture of acetonitrile: water (55:45 v/v). The detection was carried out at 269 nm using caffeine as an internal standard. The linearity was found to be 10 to 60μg/ml injection with correlation coefficient of 0.999. The percentage recovery was found to be 99.24± 1.064 to 102.66±1.22. The result of analysis of marketed formulation was found to be 99.09±0.473 to 99.55±0.493%. The method was validated and studied for the various parameters like accuracy, precision, ruggedness and specificity study . The proposed method was successfully applied for the estimation of etoricoxib in pharmaceutical dosage forms. |
---|---|
ISSN: | 0970-020X 2231-5039 |