Acute Small Bowel Perforation Caused by Obstruction of a Novel Tag-Less Agile TM Patency Capsule

A 74-year-old man visited our hospital complaining of abdominal pain. An abdominal computed tomography scan showed multiple wall thickness of the small bowel. Capsule endoscopy was recommended for further evaluation, and patency capsule examination was performed. Eighteen hours after patency capsule...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Case reports in gastroenterology 2018-05, Vol.12 (2), p.337-343
Hauptverfasser: Sawai, Katsuji, Goi, Takanori, Takegawa, Yumi, Ozaki, Yoshihiko, Taguchi, Seiichi, Kurebayashi, Hidetaka, Suto, Hiroyuki
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A 74-year-old man visited our hospital complaining of abdominal pain. An abdominal computed tomography scan showed multiple wall thickness of the small bowel. Capsule endoscopy was recommended for further evaluation, and patency capsule examination was performed. Eighteen hours after patency capsule ingestion, he experienced small bowel perforation with severe peritonitis caused by intestinal pressure rising because of the patency capsule trapped in his terminal ileum. An ileocolic resection was performed, including the removal of the sclerotic ileum as an emergency surgery. A pathological examination showed transmural inflammation and multiple ulcers with perforation of the small intestine, consistent with Crohn's disease. Here, we report a rare and valuable case of novel tag-less Agile patency capsule (Given Imaging Ltd., Yoqneam, Israel) retention leading to small bowel perforation.
ISSN:1662-0631
1662-0631