Improvement of the Mathematical Model for Determining the Dose for the TV-Type Detector in Proton Dosimetry
The results on the improvement of the mathematical model for calculating the TV-type detector are presented. The parameters of the analytical formula valid for proton energies from 60 to 200 MeV, based on the combination of parabolic cylinder functions and consistent with numerical methods and new e...
Gespeichert in:
Veröffentlicht in: | Bulletin of the Lebedev Physics Institute 2018-09, Vol.45 (9), p.287-290 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The results on the improvement of the mathematical model for calculating the TV-type detector are presented. The parameters of the analytical formula valid for proton energies from 60 to 200 MeV, based on the combination of parabolic cylinder functions and consistent with numerical methods and new experimental data, are determined. |
---|---|