Utilization of outer-midplane collector probes with isotopically enriched tungsten tracer particles for impurity transport studies in the scrape-off layer of DIII-D (invited)

Triplet sets of replaceable graphite rod collector probes (CPs), each with collection surfaces on opposing faces and oriented normal to the magnetic field, were inserted at the outboard mid-plane of DIII-D to study divertor tungsten (W) transport in the Scrape-Off Layer (SOL). Each CP collects parti...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Review of scientific instruments 2018-10, Vol.89 (10), p.10I115-10I115
Hauptverfasser: Donovan, D. C., Unterberg, E. A., Stangeby, P. C., Zamperini, S., Auxier, J. D., Rudakov, D. L., Wampler, W. R., Zach, M., Abrams, T., Duran, J. D., Elder, J. D., Neff, A. L.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Triplet sets of replaceable graphite rod collector probes (CPs), each with collection surfaces on opposing faces and oriented normal to the magnetic field, were inserted at the outboard mid-plane of DIII-D to study divertor tungsten (W) transport in the Scrape-Off Layer (SOL). Each CP collects particles along field lines with different parallel sampling lengths (determined by the rod diameters and SOL transport) giving radial profiles from the main wall inward to R-Rsep ∼ 6 cm. The CPs were deployed in a first-of-a-kind experiment using two toroidal rings of distinguishable isotopically enriched, W-coated divertor tiles installed at 2 poloidal locations in the divertor. Post-mortem Rutherford backscatter spectrometry of the surface of the CPs provided areal density profiles of elemental W coverage. Higher W content was measured on the probe side facing along the field lines toward the inner target indicating higher concentration of W in the plasma upstream of the CP, even though the W-coated rings were in the outer target region of the divertor. Inductively coupled plasma mass spectroscopy validates the isotopic tracer technique through analysis of CPs exposed during L-mode discharges with the outer strike point on the isotopically enriched W coated-tile ring. The contribution from each divertor ring of W to the deposition profiles found on the mid-plane collector probes was able to be de-convoluted using a stable isotope mixing model. The results provided quantitative information on the W source and transport from specific poloidal locations within the lower divertor region.
ISSN:0034-6748
1089-7623
DOI:10.1063/1.5039347