Indoor air quality and occupants' ventilation habits in China: Seasonal measurement and long-term monitoring

It is very important to know the current level of indoor pollution and occupants' ventilation habits. With this aim, this study presents an investigative project that covered five climate zones in China. The project consisted of two parts: long-term monitoring and seasonal measurements. For the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Building and environment 2018-09, Vol.142, p.119-129
Hauptverfasser: Liu, Junjie, Dai, Xilei, Li, Xiangdong, Jia, Susu, Pei, Jingjing, Sun, Yuexia, Lai, Dayi, Shen, Xiong, Sun, Hejiang, Yin, Haiguo, Huang, Kailiang, Tan, Hongwei, Gao, Yao, Jian, Yiwen
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:It is very important to know the current level of indoor pollution and occupants' ventilation habits. With this aim, this study presents an investigative project that covered five climate zones in China. The project consisted of two parts: long-term monitoring and seasonal measurements. For the long-term monitoring, we installed indoor air quality (IAQ) sensors, window state sensors, and mechanical ventilation sensors inside homes. In regard to IAQ, The median indoor 24-h averaged PM2.5 concentration ranged from 18 to 49 μg/m3. The indoor and outdoor 24-h averaged PM2.5 concentrations were similar for most of the regions. The 24-h averaged indoor CO2 concentrations were lower than 1000 ppm for all regions in all four seasons. Northern China usually had higher indoor CO2 concentrations than did southern China. In regard to occupants' behavior, in naturally ventilated homes, both the window-opening probability and open-window duration per day increased from the north to the south of China in winter. According to the example of mechanically ventilated Apartments, where pressure sensors were used to monitor the relative pressure at the air outlet of a mechanical ventilation system, the occupants used the ventilation system mainly in winter and spring. For the seasonal investigation, indoor formaldehyde concentrations in 224 homes were measured in four seasons (sampling time: 20 min). In summer, the indoor formaldehyde concentration reached its peak for the year, with about 35% of homes having concentrations larger than 100 μg/m3 under closed conditions (doors and windows have been closed for more than 12 h). •The median indoor 24-h PM2.5 concentration ranged from 18 to 49 μg/m3 in China.•The mean indoor 24-h CO2 concentrations were lower than 1000 ppm in all regions in the four seasons.•Statistic results of indoor pollutant concentration in China are presented.•The open-window duration increased from the north to the south of China in winter.
ISSN:0360-1323
1873-684X
DOI:10.1016/j.buildenv.2018.06.002