Comparison of the high-temperature chloride-induced corrosion between duplex steel and Ni based alloy in presence of H^sub 2^S
Duplex steel 1.4462 and Ni-based alloy Centralloy ET45 micro were tested in HCl- and H2S-containing atmospheres at 680 °C for 24, 72 and 240 h. Corroded samples were investigated by metallography, SEM/EDX and XRD. Corrosion products on the surface consisted of Cr2O3 and chromium sulfides. Beneath th...
Gespeichert in:
Veröffentlicht in: | Corrosion science 2018-07, Vol.139, p.76 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Duplex steel 1.4462 and Ni-based alloy Centralloy ET45 micro were tested in HCl- and H2S-containing atmospheres at 680 °C for 24, 72 and 240 h. Corroded samples were investigated by metallography, SEM/EDX and XRD. Corrosion products on the surface consisted of Cr2O3 and chromium sulfides. Beneath this surface layer, iron and chromium chloride were found. A depletion of iron was observed due to formation of volatile iron chloride. Both materials displayed a selective attack of the existing phases. The ferrite phase of the Duplex steel was attacked, while the Ni-based alloy showed the selective attack of chromium carbides. |
---|---|
ISSN: | 0010-938X 1879-0496 |