Compact vacuum phototriodes for operation in strong magnetic field

The results of tests of 1'' vacuum phototriodes in a magnetic field up to 4.5 T are presented. It was found that output amplitude decreases by about 6 % per tesla in the magnetic field range from 2.0 to 4.0 T. For devices with an anode mesh pitch of 16\(\mu\)m, the output amplitude at 4.0...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:arXiv.org 2001-02
Hauptverfasser: Achasov, M N, Baryshev, B A, Beloborodov, K I, Bozhenok, A V, Burdin, S V, Golubev, V B, Pyata, E E, Serednyakov, S I, Stepanenko, Z I, Tikhonov, Yu A, Vorobyov, P V
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The results of tests of 1'' vacuum phototriodes in a magnetic field up to 4.5 T are presented. It was found that output amplitude decreases by about 6 % per tesla in the magnetic field range from 2.0 to 4.0 T. For devices with an anode mesh pitch of 16\(\mu\)m, the output amplitude at 4.0 T is 30 % lower than that at zero field.
ISSN:2331-8422
DOI:10.48550/arxiv.0102083