Simulation of the response functions of Extended Range Neutron Multisphere Spectrometer using FLUKA program
In this paper, the distribution of radiation field in the CSNS spectrometer hall was simulated by FLUKA program. The results showed that the radiation field of high energy proton accelerator is dominated by neutron radiation, and the range of neutron energy is quite widely, including about eleven or...
Gespeichert in:
Veröffentlicht in: | arXiv.org 2014-09 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In this paper, the distribution of radiation field in the CSNS spectrometer hall was simulated by FLUKA program. The results showed that the radiation field of high energy proton accelerator is dominated by neutron radiation, and the range of neutron energy is quite widely, including about eleven orders of magnitude. Nextly, work of simulation and calculation of the response functions of four Bonner spheres with simplified model is done by FLUKA and MCNP codes respectively, and the acceptable difference proved the feasibility of FLUKA program in this application and the correctness of the relevant calculation method. Through adopting the actual model, we simulate and calculate the energy response functions of Bonner sphere detectors with polyethylene layers of different diameters, including the detectors with lead layers by using FLUKA code. According to the simulation results, we select eleven detectors as the basic structure of ERNMS. |
---|---|