Assessing the airtightness performance of container houses in relation to its effect on energy efficiency

This study examines the airtightness performance of four types of commonly-used container houses (CHs) and its impact on their energy efficiency. One of the CHs was treated by sealing all junctions inside the container envelope. The airtightness levels of unsealed and sealed CHs were measured by usi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Building and environment 2018-04, Vol.134, p.59-73
Hauptverfasser: Tanyer, Ali Murat, Tavukcuoglu, Ayse, Bekboliev, Mirbek
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This study examines the airtightness performance of four types of commonly-used container houses (CHs) and its impact on their energy efficiency. One of the CHs was treated by sealing all junctions inside the container envelope. The airtightness levels of unsealed and sealed CHs were measured by using the fan pressurization method. The interior surfaces of building envelope were scanned by thermal imaging in order to locate the areas suffering from air leakages and thermal failures. The annual energy consumptions of unsealed and sealed CHs for their heating were predicted by energy simulation analyses. The unsealed CHs have poor airtightness features while performing in Energy Rating B category. The junctions of those houses, especially where wall, slab and roof panels come together and the edges of the openings also suffer from air leakages, thermal bridges and condensation. Sealing the interior surfaces of junctions and edges improves the airtightness level considerably while heat loss and condensation problems at the junctions still continue. An 81% improvement in airtightness performance of the CH Type B provided a reduction of 9.3% in annual energy demand which is not enough to step up its Energy Rating category. The results indicate that airtight jointing is needed at junctions while the use of thermal breaks at junction details has vital importance to eliminate thermal failures and to improve energy efficiency performance of CHs. The combined use of Blower Test Method and Infrared Thermography is useful for non-destructive assessment of airtightness features of building envelopes. •Selected container houses perform in Energy Rating B and suffer from poor airtightness.•Air leakages at junctions are the main reasons of poor airtightness.•Sealing the junctions provide significant improvement in airtightness.•Sealing is not enough to eliminate thermal failures in building envelope.•Blower Door Test and IR Thermography are useful to assess airtightness performance.
ISSN:0360-1323
1873-684X
DOI:10.1016/j.buildenv.2018.02.026