A comparative study of various electrochemical sensors for hydrazine detection based on imidazole derivative and different nano-materials of MCM-41, RGO and MWCNTs: Using net analyte signal (NAS) for simultaneous determination of hydrazine and phenol

The present paper reports using 5-(5-chloro-2,4-dihydroxyphenyl)imidazo[4,5-d] [1,3]thiazin-7(3H)-one (CIT) and different characterized nano-materials (nano particles based on silica (MCM-41)) and carbon (reduced graphene oxide (RGO), carbon Nano-tubes (CNT) and the mixture of them (CNT/RGO)) in the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of electroanalytical chemistry (Lausanne, Switzerland) Switzerland), 2017-02, Vol.787, p.145-157
Hauptverfasser: Benvidi, Ali, Nikmanesh, Maryam, Dehghan Tezerjani, Marzieh, Jahanbani, Shahriar, Abdollahi, Mohammad, Akbari, Ali, Rezaeipoor-Anari, Ali
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The present paper reports using 5-(5-chloro-2,4-dihydroxyphenyl)imidazo[4,5-d] [1,3]thiazin-7(3H)-one (CIT) and different characterized nano-materials (nano particles based on silica (MCM-41)) and carbon (reduced graphene oxide (RGO), carbon Nano-tubes (CNT) and the mixture of them (CNT/RGO)) in the carbon pate electrode (CPE) structure as new platforms for hydrazine determination. The main purpose of this paper is investigation of effect of silica and carbon nanomaterials on the electrochemical behaviour of the various designed sensors (CIT/MCM41/CPE, CIT/RGO/CNT/CPE, CIT/RGO/CPE and CIT/CNT/CPE) for hydrazine analysis. Under the optimum conditions, some kinetic parameters of modifier such as electron transfer coefficient (α) and heterogeneous rate constant (k) for hydrazine were obtained. The observations revealed that using nanomaterials of MCM-41, RGO, CNT and RGO/CNT has a key role in decreasing oxidation potential and increasing oxidation peak currents, obtaining wider linear range and lower detection limit. The results indicated that CIT/MCM41/CPE sensor possess two linear ranges (0.01–0.032μM and 1.0–200μM) and a lower detection limit (0.0033μM based on 3Sb/m) than other fabricated sensors. The designed sensor was used for simultaneous determination of hydrazine and phenol. The obtained differential pulse voltammograms indicated overlapping and to solve this problem, net analyte signal (NAS) was used.
ISSN:1572-6657
1873-2569
DOI:10.1016/j.jelechem.2017.01.006