Comparison of fatigue crack growth stress ratio effects under simple variable amplitude loading using fractographic and strain measurements

•Crack closure measurements depend on the location of the gauge.•Stress ratio effects are not the result of closure in the crack wake.•Constant amplitude bands can be measured within variable amplitude loading.•Crack growth for low stress ratios is lower for variable amplitude loading. Crack closure...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International journal of fatigue 2018-07, Vol.112, p.240-252
Hauptverfasser: White, P.D., Barter, S.A., Medhekar, N.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:•Crack closure measurements depend on the location of the gauge.•Stress ratio effects are not the result of closure in the crack wake.•Constant amplitude bands can be measured within variable amplitude loading.•Crack growth for low stress ratios is lower for variable amplitude loading. Crack closure, the contact between opposing crack faces above zero load, has traditionally been used to explain the observation that higher stress ratio fatigue cycles have faster growth rates than lower stress ratio cycles. Using new techniques to investigate the dependance of stress ratio on crack closure, we tested simplified variable amplitude loading sequences containing segments of 100 cycles at different stress ratios in AA7050-T7451 alloy. We compared the crack growth at different stress ratios at the start of a coupon with no closure and after 5 mm or more of crack growth where significant closure had developed as indicated by side and back-face strain gauges mounted on the coupon. Fractographic measurements of the fatigue growth from these sequences show the same stress ratio effect at the start of loading and after 5 mm of growth, suggesting that the stress ratio effect occurs soon after the commencement of growth and that crack closure is not the dominant cause of the stress ratio effect in the AA7050-T7451 alloy. Results from these tests using constant and varying maximum stress intensity Kmax also showed significantly different stress ratio effects. Traditional constant amplitude load tests over-predict the rate of crack growth for cycles in which the maximum load is varying. Obtaining crack growth rates for a range of different stress ratios from variable amplitude testing in this way can allow greater accuracy to be achieved in predicting the rate of crack growth for arbitrary variable amplitude loading sequences.
ISSN:0142-1123
1879-3452
DOI:10.1016/j.ijfatigue.2018.01.035