A Carrier-Based PWM for Three-Level T-Type Inverter to Tolerate Open-Circuit Fault
This paper investigates the open-circuit faults of switching devices in the three-level T-Type inverter and proposes a new tolerant control method. The three-phase current and variation of the neutral-point voltage are detected to determine the fault switch. A carrier-based pulse width modulation is...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on power electronics 2018-10, Vol.33 (10), p.8787-8796 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This paper investigates the open-circuit faults of switching devices in the three-level T-Type inverter and proposes a new tolerant control method. The three-phase current and variation of the neutral-point voltage are detected to determine the fault switch. A carrier-based pulse width modulation is developed to tolerate switch fault by transiting from three-level to two-level switching. This makes the modulation scheme easier to be implemented compared to space vector modulation. For the neutral-point fault, the fault phase is operated by two-level modulation to produce the same rating voltage. On the other hand, the inverter is able to produce balanced voltage with reduced rating by keeping the phase of half-bridge fault to the neutral-point voltage. The neutral-point voltage is also able to be balanced by using two-level modulation since it does not contribute the neutral-point current. The performance and effectiveness of the proposed tolerant control are verified by a laboratory build. |
---|---|
ISSN: | 0885-8993 1941-0107 |
DOI: | 10.1109/TPEL.2017.2779472 |